Assessment of Liver Fibrosis with Diffusion-Weighted Magnetic Resonance Imaging Using Different b-values in Chronic Viral Hepatitis

نویسندگان

  • Ercan Kocakoc
  • Ayse Ahsen Bakan
  • Orhan Kursat Poyrazoglu
  • Adile Ferda Dagli
  • Yeliz Gul
  • Mehtap Cicekci
  • Ibrahim Halil Bahcecioglu
چکیده

OBJECTIVE To examine the effectiveness of apparent diffusion coefficient (ADC) values and to compare the reliability of different b-values in detecting and identifying significant liver fibrosis. SUBJECTS AND METHODS There were 44 patients with chronic viral hepatitis (CVH) in the study group and 30 healthy participants in the control group. Diffusion-weighted magnetic resonance imaging (DWI) was performed before the liver biopsy in patients with CVH. The values of ADC were measured with 3 different b-values (100, 600, 1,000 s/mm2). In addition, liver fibrosis was classified using the modified Ishak scoring system. Liver fibrosis stages and ADC values were compared using areas under the receiver-operating characteristic (ROC) curve. RESULTS The study group's mean ADC value was not statistically significantly different from the control group's mean ADC value at b = 100 s/mm2 (3.69 ± 0.5 × 10-3 vs. 3.7 ± 0.3 × 10-3 mm2/s) and b = 600 s/mm2 (2.40 ± 0.3 × 10-3 vs. 2.5 ± 0.5 × 10-3 mm2/s). However, the study group's mean ADC value (0.99 ± 0.3 × 10-3 mm2/s) was significantly lower than that of the control group (1.2 ± 0.1 × 10-3 mm2/s) at b = 1,000 s/mm2. With b = 1,000 s/mm2 and the cutoff ADC value of 0.0011 mm2/s for the diagnosis of liver fibrosis, the mean area under the ROC curve was 0.702 ± 0.07 (p = 0.0015). For b = 1,000 s/mm2 and the cutoff ADC value of 0.0011 mm2/s to diagnose significant liver fibrosis (Ishak score = 3), the mean area under the ROC curve was 0.759 ± 0.07 (p = 0.0001). CONCLUSION Measurement of ADC values by DWI was effective in detecting liver fibrosis and accurately identifying significant liver fibrosis when a b-value of 1,000 s/mm2 was used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of diagnostic value of DWI technique in the evaluation of liver fibrosis

Introduction: The liver fibrosis is caused by extracellular accumulation of cluster, glycos amino glycans and proteoglycans, which this extracellular accumulation may limit the penetration and molecular movement of water in the tissue, so the Diffusion weighted imaging(DWI) technique is due to the sensitivity to the movement and release of water molecules Can show this restrict...

متن کامل

Diffusion weighted MRI in chronic viral hepatitis: correlation between ADC values and histopathological scores

OBJECTIVE To investigate the utility of apparent diffusion coefficient (ADC) measurement in the diagnosis of chronic viral hepatitis (CVH) and correlation between ADC values and histopathologic severity of CVH. MATERIALS AND METHODS The ADC values of liver parenchyma on diffusion-weighted magnetic resonance imaging (DWMRI) were measured in 50 patients with a history of CVH and 51 healthy subj...

متن کامل

Diffusion Weighted MRI for Hepatic Fibrosis: Impact of b-Value

BACKGROUND Hepatic fibrosis is a typical complication of chronic liver diseases resulting in cirrhosis that remains a major public health problem worldwide. Liver biopsy is currently the gold standard for diagnosing and staging hepatic fibrosis. Percutaneous liver biopsy; however, is an invasive procedure with risks of complications. Therefore, there is need for alternative non-invasive techniq...

متن کامل

Cardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging

Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magne...

متن کامل

Magnetic Resonance Elastography and Diffusion Weighted Imaging in the Evaluation of Hepatic Fibrosis in Chronic Hepatitis B

Background/Aims Comparison of the accuracy of magnetic resonance elastography (MRE) and diffusion weighted imaging (DWI) for the diagnosis of liver fibrosis in patients with chronic hepatitis B (CHB). Methods In this retrospective analysis, we investigated 63 patients with CHB and liver fibrosis. DWI was performed with both breath-hold (DWI-BH) and free-breathing (DWI-FB) sequences (b=0, 500)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2015