Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (II) modeling oxygen diffusion.
نویسندگان
چکیده
Oxygen contamination of a polyacrylamide gel (PAG) dosimeter can have a significant detrimental effect upon the performance characteristics of the gel as a dosimeter. Oxygen contamination can occur during preparation, but can also arise from the diffusion of atmospheric oxygen through vessel walls. Even 'trace' amounts of oxygen present in any gaseous space (usually nitrogen filled) between the surface of the PAG and the vessel seal can have a detectable effect. This paper describes a method used to quantify the detrimental effects of a range of oxygen concentrations upon the performance of the PAG. The results of diffusion studies for air and pure oxygen diffusing into the PAG over time are presented and coupled with a novel method of calculating oxygen concentrations in the PAG. Results obtained suggest that the diffusion is Fickian. The coefficient of diffusion D has been calculated to be (8+/-2) x 10(-6) cm2 s(-1) for oxygen diffusing into PAG stored at 4 degrees C, under the assumption that the diffusion mechanism is independent of the concentration of the diffusing species. In addition, a quantitative relation has been established between the transverse relaxation rate R2 of the PAG and the concentration of oxygen present. The implications of these findings for polymer gel dosimetry are discussed.
منابع مشابه
Temperature increases associated with polymerization of irradiated PAG dosimeters.
Polyacrylamide gel (PAG) dosimeters show considerable promise as three-dimensional dosimeters for the verification of complex dose distributions associated with conformal therapy. However, the potential of PAG dosimeters has not yet been borne out in clinical practice and it is apparent that basic investigations of these dosimeters are still required. The polymerization reactions in PAG dosimet...
متن کاملEvaluation of the radiation-sensitizer/protector and/or antioxidant efficiencies using Fricke and PAG dosimeters
In this study, our aim is to assess the potential of Fricke and polyacrylamide gel (PAG) dosimeters to quantitatively evaluate the efficiency of potential radiation sensitizers/protectors and antioxidants. These compounds are of importance in radiotherapy as well as in disease prevention and promotion of health. The basic principle of the Fricke dosimeter is the radiation-induced oxidation of F...
متن کاملComment on 'The influence of antioxidant THPC on the properties of polymer gel dosimeter'.
In order to decrease the negative influence of oxygen to the response of PAG dosimeters THPC has been added to the gel in the role of scavenger. Apart from the decreased influence of oxygen, THPC also influences other properties of gel dosimeters. This study examines these influences and their quantification. Previous studies have shown that increasing the concentration of THPC causes a decreas...
متن کاملEnhancement of Dose Response and Nuclear Magnetic Resonance Image of PAGAT Polymer Gel Dosimeter by Adding Silver Nanoparticles
In the present study, the normoxic polyacrylamide gelatin and tetrakis hydroxy methyl phosphoniun chloride (PAGAT) polymer gel dosimeters were synthesized with and without the presence of silver (Ag) nanoparticles. The amount of Ag nanoparticles varied from 1 to 3 ml with concentration 3.14 g/l, thus forming two types of PAGAT polymer gel dosimeters before irradiating them with 6 to 25 Gy produ...
متن کاملImmunological characteristics of the glycolipid antigen of Leptospira interrogans serovar lai.
The protective antigen (PAg), a glycolipid substance, was extracted from Leptospira interrogans serovar lai strain 017 with a chloroform-methanol-water (1:2:0.8 [vol/vol/vol]) solution and partially purified by silica gel column chromatography. The PAg was not detected by Coomassie brilliant blue staining in sodium dodecyl sulfate-polyacrylamide gel electrophoresis but was observed as a smearli...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 44 8 شماره
صفحات -
تاریخ انتشار 1999