Smear layer removal in canals shaped with reciprocating rotary systems
نویسندگان
چکیده
The aim was to assess the presence of smear layer after canal instrumentation with two reciprocating rotary systems and a continuous motion one. Thirty canals were shaped with Reciproc, WaveOne or Mtwo systems. Smear layer was assessed following a three value scale at coronal, middle and apical levels with a scanning electron microscopy. Reciproc scores: coronal third, 20% of the cases: 0, 60%: 1, 20%: 2; middle third, 10%: 0, 20%: 1, 70%:2; apical third: 2 in all cases. WaveOne scores: coronal third, 0 (40%), 1 (30%) and 2 (30%); middle third, 0 (20%), 1 (50%), 2 (30%); apical third, 0 (20%), 2 (80%) of cases. MTwo scores: coronal third 0 (50%), 1 (30%) 2 (20%); middle third 0 (20%), 1 (50%), 2 (30%); apical third, 0 (10%), 1 (10%), 2 (80%). No significant differences (p>0.05) were found between the three used systems. Key words:Endodontics, reciprocating motion files, rotary file, SEM, smear layer.
منابع مشابه
Preparation of the coronal and middle third of oval root canals with a rotary or an oscillating system.
OBJECTIVES To comparatively evaluate the preparation of oval root canals with a rotary or an oscillating system. STUDY DESIGN The middle and coronal parts of 55 extracted permanent teeth with oval canals were prepared using FlexMaster (FM) rotary NiTi instruments and EndoEze AET (EE) stainless steel oscillating instruments. Pre- and postoperative images of cross-sections were superimposed to ...
متن کاملEvaluation of Effectiveness of Cleaning of Root Canals using Protaper and K3 Rotary Systems: A SEm Study
The aim of this in vitro study was to compare the debris and smear layer removal following root canal preparation using two different rotary systems with scanning electron microscope (SEM). The rotary systems used were Protaper and K3. Forty single rooted permanent mandibular premolars were chosen for the study. They were assigned two groups on the basis of instrumentation used. The teeth were ...
متن کاملDebris Evaluation after Root Canal Shaping with Rotating and Reciprocating Single-File Systems
This study evaluated the root canal dentine surface by scanning electron microscope (SEM) after shaping with two reciprocating single-file NiTi systems and two rotating single-file NiTi systems, in order to verify the presence/absence of the smear layer and the presence/absence of open tubules along the walls of each sample; Forty-eight single-rooted teeth were divided into four groups and shap...
متن کاملEffect of aquatine endodontic cleanser on smear layer removal in the root canals of ex vivo human teeth
OBJECTIVES The purpose of this study was to measure and compare the root canal cleanliness and smear layer removal effectiveness of Aquatine Endodontic Cleanser (Aquatine EC) when used as an endodontic irrigating solution in comparison with 6% sodium hypochlorite (NaOCl). MATERIAL AND METHODS Forty-five human teeth were randomly allocated to five treatment groups; the pulp chamber was accesse...
متن کاملEffects of irrigation on debris and smear layer on canal walls prepared by two rotary techniques: a scanning electron microscopic study.
Debris and smear layer were evaluated in canals prepared with either Lightspeed (LS) or ProFile (PF) rotary instruments. Irrigants used were tap water (group A) or alternating 5.25% NaOCl and 17% EDTA (group B). Apical stops were prepared to size 52.5 in the LS and to size 6 (approximately ISO size 36) in the PF techniques. The roots were split longitudinally and examined at apical, middle and ...
متن کامل