Accuracy of Protein Size Estimates Based on Light Scattering Measurements

نویسندگان

  • Ken Takeuchi
  • Yoichi Nakatani
  • Osamu Hisatomi
چکیده

There are two types of light scattering measurements: static light scattering (SLS) and dynamic light scattering (DLS). The SLS method is used to estimate the molecular weight (MW) of particles by measuring the time-averaged intensity of light scattered by the particles, whereas the DLS method is used to estimate the diffusion coefficient of particles by observing the time-correlation of scattered light intensity. These techniques have recently been applied to the investigation of the aggregation, denaturation and folding, and complex formation of proteins in solution. However, the accuracy of protein size measurement by light scattering is poorly understood. In the present study, we carried out the size measurements of five globular proteins by SLS and DLS at a detection angle of 90 ̊ and compared these data to measurements made by size exclusion chromatography (SEC). The difference (%) between the MW estimated from each method and the MW calculated from the amino acid sequence (namely the calibration residual error) was regarded as an index of measurement accuracy. The averaged calibration residual errors were 5.2 and 4.7 for SEC and SLS measurements, respectively. For the DLS measurements, the extrapolation of the apparent hydrodynamic radii to a protein concentration of zero may effectively eliminate the interparticle and hydrodynamic interactions and significantly reduced the averaged calibration residual error to 4.8%. Our results suggested that the size of globular proteins can be estimated using light scattering measurements with an accuracy equivalent to that of SEC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biophysical Studies on the Interaction of Insulin with a Cationic Gemini Surfactant

A novel quaternary ammonium-based cationic gemini surfactant (S6) having 1,6 di-bromo hexane as a spacer, have been used and its interaction with insulin in aqueous solution (pH, 7.40) was investigated by several methods including fluorescence spectroscopy, UV-Vis spectroscopy, circular dichroism, dynamic light scattering, ζ-potential measurements, conductivity and transmission electron microsc...

متن کامل

Effect of tocopherol on Pluronic microemulsions: turbidity studies and Dynamic light scattering and dynamic surface tension measurements

The development and design of the biocompatible and biodegradable thermodynamically stable micellar and microemulsion transparent dispersions to reduce the free and unbounded drugs concentration in the blood is a basic challenge in field of drug efficacy and bioavailability of drugs. In the current work, solubilization capacity of the drug (Tocopherol), oil (Ethyl Butyrate), and oil+drug (1:1 m...

متن کامل

Determination of the size distribution of monodesperse and bidisperse mixtures of spherical particles in the nanometer and submicron size range by applying cumulant analysis and contin algorithm in dynamic light scattering

Determination of particle size is one of the major needs in the industry and biotechnology. Dynamic light scattering (DLS) is a widely used technique for determining size distribution of spherical particle in nanometer and submicron size range. In this method, there are different algorithms for determining the size and size distribution of particles, which are selected according to the required...

متن کامل

Theoretical Analysis of PM2.5 Mass Measurements by Nephelometry

With the recently promulgated PM2.5 mass standards, a need has appeared for continuous PM2.5 mass measuring instrumentation to complement standard filter based aerosol samplers. It is generally accepted that in most cases, the PM2.5 mass distribution and light scattering is dominated by particles with diameters in the size range 0.1–1.0μm. Early field studies indicated a reasonable correlation ...

متن کامل

اثر شفافیت الکترولیت بر پس‌پراکندگی نور از لایه پس‌پراکننده نوری در سلول‌های خورشیدی رنگدانه‌ای

Conventionally, a film of TiO2 particles of ~300 nm size is employed in DSCs as the back reflector film to enhance the light harvesting. In this study, two electrolytes with different transparencies, iodide-based and cobalt-based electrolytes, were used to investigate the transparency effect of electrolytes on light back-scattering from back scattering layer and also to study its effect on the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014