Analysis of Blood Serum on the Liberty Series II ICP OES with the Axially- Viewed Plasma
نویسنده
چکیده
Disadvantages of flame AA are that releasing agents or modifiers are necessary and careful control of the flame stoichiometry is important to overcome chemical interferences [1]. While the atomic absorption technique offers adequate performance, in most cases it is a single element technique and is therefore slow. Analysis of Blood Serum on the Liberty Series II ICP OES with the AxiallyViewed Plasma
منابع مشابه
Matrix effects on the determination of dysprosium, europium and ytterbium used as animal faecal markers by inductively coupled plasma optical emission spectrometry with axially- and radially- viewed configurations
Matrix effects were evaluated on the determination of Dy, Eu and Yb used as sheep faecal markers by inductively coupled plasma optical emission spectrometry (ICP-OES) with axiallyand radially-viewed configurations. The samples were prepared with microwave-assisted acid digestion using an oven with closed vessels. The analytical performances of the two ICP-OES instruments were compared using Mg ...
متن کاملA Complete Method for Environmental Samples by Simultaneous Axially Viewed ICP- OES following US EPA Guidelines Authors
The Vista instrument has a number of distinct advantages over similar ICP-OES systems. Firstly, the VistaChip is the only single Charge Coupled Device (CCD) that allows full coverage of the spectrum from 165-785nm, with a pixel processing speed of 1 MHz and exceptional anti-blooming properties. These features allow both trace level analytes and major analytes to be determined in the same measur...
متن کاملLinear and Nonlinear Multivariate Classification of Iranian Bottled Mineral Waters According to Their Elemental Content Determined by ICP-OES
The combinations of inductively coupled plasma-optical emission spectrometry (ICP-OES) and three classification algorithms, i.e., partial least squares discriminant analysis (PLS-DA), least squares support vector machine (LS-SVM) and soft independent modeling of class analogies (SIMCA), for discriminating different brands of Iranian bottled mineral waters, were explored. ICP-OES was used for th...
متن کاملDetermination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
متن کاملDetermination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression
A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...
متن کامل