An approach for the efficiency calibration of whole body counters.
نویسندگان
چکیده
An approach is outlined for the evaluation of the efficiency of whole body counters using experimental data for a point source and Monte Carlo simulation of the efficiency of photon arrival at a large volume NaI(Tl) detector. The approach was applied to the measurement of an experimental whole body phantom. The experimental and the predicted efficiencies were found to differ from -2.5% to 8.4%. An investigation of the geometry dependence of the counting efficiency was made using theoretical dimensions of phantoms of different sizes. The relative geometry dependence was found to be less than 9% for the "Reference Man" and "Reference 10-y-old Child" phantoms.
منابع مشابه
An Intercomparison of Counting Efficiency and the Performance of Two Whole-Body Counters According to the Type of Phantom
Background: Whole-body counters are widely used to evaluate internal contamination of the internal presence of gamma-emitting radionuclides. In internal dosimetry, it is a basic requirement that quality control procedures be applied to verify the reliability of the measured results. The implementation of intercomparison programs plays an important role in quality control, and the accuracy of th...
متن کاملIndividual Calibration of Whole-body and Partial-body Counters by Means of Voxel Phantoms
accuracy of activity determination by means of whole-body and partial-body counters is no longer determined by errors in counting statistics, but by the bias caused by calibration. This is true in particular of low-energy photon emitters, such as Pb-210, U-235, Th-234 (daughter product of U-238), and Am-241. In addition, these nuclides in general show a very inhomogeneous distribution in the bo...
متن کاملWhole body phantoms for the determination of dosimetry parameters needs for patients in nuclear medicine [Persian]
This study aims to give data concrning phantom material made in Iran i'rom a natural rubber which is used for obtaining calibration data for patient dose measurements in nuclear medicine applications of radionuclides for therapy and diagnosis. Is showed to be a tissue equivalent material cheap (25000 Rials the material itself and 35000 Rials the process of casting and moulding etc.), easi...
متن کاملKinematic runoff and erosion model efficiency assessment for hydrological simulation of semi-arid watersheds
Hydrologic modeling of semi-arid watersheds is imperative for the development of appropriate water and soil conservation plans. In the current study, the efficiency of Kinematic Runoff and Erosion model-version 2 (K2) model was used to evaluate water discharge and sediment load simulation of Bar watershed, located in the north-eastern part of Iran. The K2 model relies on the kinematic wave appr...
متن کاملA New Approach to Self-Localization for Mobile Robots Using Sensor Data Fusion
This paper proposes a new approach for calibration of dead reckoning process. Using the well-known UMBmark (University of Michigan Benchmark) is not sufficient for a desirable calibration of dead reckoning. Besides, existing calibration methods usually require explicit measurement of actual motion of the robot. Some recent methods use the smart encoder trailer or long range finder sensors such ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Health physics
دوره 81 5 شماره
صفحات -
تاریخ انتشار 2001