Randomised trial spacer v nebuliser for acute asthma.

نویسندگان

  • P C Parkin
  • N R Saunders
  • S A Diamond
  • P M Winders
  • C Macarthur
چکیده

Sixty hospitalised children with asthma aged 1-5 years were randomised to spacer or nebuliser. A clinical score was measured at baseline and every 12 hours. There were no differences between groups in the score over time, or secondary outcome measures. The spacer is an effective delivery method for young hospitalised asthmatic children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomised controlled trial to assess the relative benefits of large volume spacers and nebulisers to treat acute asthma in hospital.

OBJECTIVES To compare the clinical effectiveness, acceptability, and cost benefit of administering beta2 agonists by means of a metered dose inhaler and large volume spacer with conventional nebulisers to children admitted to hospital with acute asthma. METHODS A randomised controlled trial was conducted over five months. Sixty one children older than 3 years admitted to a large teaching hosp...

متن کامل

Comparison between efficacy of MDI+spacer and nebuliser in the management of acute asthma in children.

BACKGROUND Due to changing evidence on efficacy of MDI+spacer as compared to nebuliser, two types of managements were going on in our Day unit, depending on the presence of different medical professionals. We wanted to find out the evidence of the best practice from within our unit, and then to formulate guidelines based on it for the management of paediatric acute asthma. METHODS We isolated...

متن کامل

Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma.

BACKGROUND In acute asthma inhaled beta(2)-agonists are often administered by nebuliser to relieve bronchospasm, but some have argued that metered-dose inhalers with a holding chamber (spacer) can be equally effective. Nebulisers require a power source and need regular maintenance, and are more expensive in the community setting. OBJECTIVES To assess the effects of holding chambers (spacers) ...

متن کامل

Domiciliary comparison of terbutaline treatment by metered dose inhaler with and without conical spacer in severe and moderately severe chronic asthma.

The bronchodilator response to cumulative doses of terbutaline administered by metered dose inhaler with and without a conical spacer device and by Acorn nebuliser has been compared in groups of patients with chronic severe and moderately severe asthma. After laboratory studies the patients undertook a randomised domiciliary crossover comparison of bronchodilator response to terbutaline given b...

متن کامل

Metered dose inhaler and nebuliser in acute asthma.

One hundred and eleven children with acute asthma were studied to compare delivery of terbutaline by either a metered dose inhaler (MDI) with a valved holding chamber or a nebuliser driven by air. Eligible patients were randomised; the MDI group received three puffs (0.75 mg) of terbutaline and the nebuliser group received 2 ml (5.0 mg) terbutaline solution diluted with 2 ml 0.9% saline for inh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 72 3  شماره 

صفحات  -

تاریخ انتشار 1995