Influence of B1-Inhomogeneity on Pharmacokinetic Modeling of Dynamic Contrast-Enhanced MRI: A Simulation Study
نویسندگان
چکیده
OBJECTIVE To simulate the B1-inhomogeneity-induced variation of pharmacokinetic parameters on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). MATERIALS AND METHODS B1-inhomogeneity-induced flip angle (FA) variation was estimated in a phantom study. Monte Carlo simulation was performed to assess the FA-deviation-induced measurement error of the pre-contrast R1, contrast-enhancement ratio, Gd-concentration, and two-compartment pharmacokinetic parameters (Ktrans, ve, and vp). RESULTS B1-inhomogeneity resulted in -23-5% fluctuations (95% confidence interval [CI] of % error) of FA. The 95% CIs of FA-dependent % errors in the gray matter and blood were as follows: -16.7-61.8% and -16.7-61.8% for the pre-contrast R1, -1.0-0.3% and -5.2-1.3% for the contrast-enhancement ratio, and -14.2-58.1% and -14.1-57.8% for the Gd-concentration, respectively. These resulted in -43.1-48.4% error for Ktrans, -32.3-48.6% error for the ve, and -43.2-48.6% error for vp. The pre-contrast R1 was more vulnerable to FA error than the contrast-enhancement ratio, and was therefore a significant cause of the Gd-concentration error. For example, a -10% FA error led to a 23.6% deviation in the pre-contrast R1, -0.4% in the contrast-enhancement ratio, and 23.6% in the Gd-concentration. In a simulated condition with a 3% FA error in a target lesion and a -10% FA error in a feeding vessel, the % errors of the pharmacokinetic parameters were -23.7% for Ktrans, -23.7% for ve, and -23.7% for vp. CONCLUSION Even a small degree of B1-inhomogeneity can cause a significant error in the measurement of pharmacokinetic parameters on DCE-MRI, while the vulnerability of the pre-contrast R1 calculations to FA deviations is a significant cause of the miscalculation.
منابع مشابه
Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملEvaluation of the accuracy of dynamic contrast enhanced MRI in the diagnosis of invasive prostate neoplasm using pathological findings
Background: Prostate cancer is the most common malignancy in men and the second leading cause of death in all countries of the world. The exact mechanism of prostate cancer is not known. On the other hand, early detection of prostate cancer can lead to a complete cure. Several clinical experiments including Digital Rectum Examination (DRE), biochemistry such as Prostate Specific Antigen (PSA), ...
متن کاملAutomatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI
Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...
متن کاملQuantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging
Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...
متن کاملFeasibility of a fast method for B1-inhomogeneity correction for FSPGR sequences.
The Fast Spoiled Gradient Echo (FSPGR) sequence is often used in MRI to create T1-weighted images. The signal intensity generated by this sequence depends on the applied flip angle. Knowing the correct flip angle is essential for the determination of T1-maps by means of an FSPGR based Variable Flip Angle (VFA) approach. Also, quantitatively determining the concentration of contrast agent in cas...
متن کامل