Variability in short-wavelength automated perimetry among peri- or postmenopausal women: a dependence on phyto-oestrogen consumption?
نویسندگان
چکیده
PURPOSE To determine whether the hill of vision for Short-Wavelength Automated Perimetry (SWAP) is shallower for women who consume phyto-oestrogen-rich foods than for women who do not. METHODS Visual field data were compared for two groups of healthy amenorrhoeic women 48-69 years-old with normal vision and not using hormone replacement: (1) 24 subjects who reported consuming soy and/or flax products and (2) 20 subjects who reported not consuming these products. Two types of 24-2 visual fields were measured: (1) Full Threshold SWAP and (2) a white-on-white (W/W) field obtained using a Swedish Interactive Threshold Algorithm (SITA Standard). RESULTS The reduction of SWAP sensitivity from the centre of the field (4 loci, mean eccentricity = 4.2°) to the periphery (20 loci, mean eccentricity = 21.9°) was less for soy/flax consumers than for nonconsumers, both with age-referencing (mean difference = 1.7 dB, p = 0.018) and without (p = 0.012). Corresponding distinctions existed for the SWAP - W/W difference, and there was minimal effect for W/W fields alone. The peripheral age-referenced SWAP sensitivities averaged 2.5 dB higher for consumers than nonconsumers (p = 0.022). CONCLUSION The between-group distinctions are consistent with the possibility (derived from the women's health literature) that phyto-oestrogens may counteract a decline of short-wavelength-sensitive cone-mediated response among postmenopausal women. These results suggest another potential application for SWAP outside its original intended purpose as a glaucoma test. Future studies should assess whether phyto-oestrogen consumption is most beneficial for women who are sufficiently young and/or not too far beyond menopause.
منابع مشابه
Association between dietary phyto-oestrogens and bone density in men and postmenopausal women.
Phyto-oestrogens have been associated with a decreased risk for osteoporosis, but results from intervention and observational studies in Western countries have been inconsistent. In the present study, we investigated the association between habitual phyto-oestrogen intake and broadband ultrasound attenuation (BUA) of the calcanaeum as a marker of bone density. We collected 7 d records of diet, ...
متن کاملEstimated intake of dietary phyto-oestrogens in Australian women and evaluation of correlates of phyto-oestrogen intake
The role of dietary phyto-oestrogens in health has been of continued interest and debate, but data available on the distribution of intake in the Australian diet are scarce. Therefore, we aimed to estimate phyto-oestrogen consumption in Australian women, describe the pattern of intake and identify correlates of high phyto-oestrogen intake. Study participants were 2078 control women (18-79 years...
متن کاملRetrobulbar blood flow and visual field alterations after acute ethanol ingestion
BACKGROUND The purpose of this study was to test the effect of ethyl alcohol on the koniocellular and magnocellular pathway of visual function and to investigate the relationship between such visual field changes and retrobulbar blood flow in healthy subjects. METHODS In 12 healthy subjects (mean age 32 ± 4 years), color Doppler imaging, short-wavelength automated perimetry, and frequency dou...
متن کاملVisual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.
PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...
متن کاملStatistical aspects of the normal visual field in short-wavelength automated perimetry.
PURPOSE To determine the intraindividual and interindividual characteristics of normal sensitivity derived by short-wavelength automated perimetry (SWAP) as a function of threshold algorithm. To determine also the influence of ocular media absorption on the magnitude of the interindividual variation in normal sensitivity, and hence the confidence limits, derived by SWAP. METHODS The sample co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta ophthalmologica
دوره 89 3 شماره
صفحات -
تاریخ انتشار 2011