THE PURPOSE Assessing the accuracy of multi parametric magnetic resonance (mp-MRI) after application of PI-RADS V2 for diagnosis of prostate cancer as comparison to pathological results of trans rectal ultra-sound (TRUS) guided biopsy. PATIENTS AND METHODS 138 prostatic lesions in 23 patients were retrospectively assessed and analyzed with Trans rectal ultra-sound (TRUS) guided biopsy results. Those patients underwent multi parametric magnetic resonance (mp-MRI) with application of PI-RADS V2 reporting system. The sensitivity, specificity, validity, negative predictive value and positive predictive value were calculated for PI-RADS V2 reporting system compared to biopsy-proven pathological results. RESULTS 92 out of 138 lesions were positive for Peripheral zone cancer prostate. PI-RADS V2 reporting system proved 88.04% sensitive & 93.4% specific for diagnosis of prostate cancer with negative predictive value & positive predictive value of 100%. CONCLUSION Our results proved that mp-MRI of prostate using PI-RADS v2 scoring system had high sensitivity and specificity in diagnosis of prostate cancer and PI-RADS V2 scoring system using mp-MRI is recommended as a non-invasive diagnostic tool compared to TRUS guided biopsy.
منابع مشابه
Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2
BACKGROUND Prostate Imaging Reporting and Data System (PI-RADS) is a globally acceptable standardization for multiparametric magnetic resonance imaging (mp-MRI) in prostate cancer (PCa) diagnosis. The American College of Radiology revised the PI-RADS to address the limitations of version 1 in December 2014. This study aimed to determine whether the PI-RADS version 2 (PI-RADS v2) scoring system ...
متن کاملThe role of different PI-RADS versions in prostate multiparametric magnetic resonance tomography assessment
Background. Standardised Prostate Imaging Reporting and Data System (PI-RADS) guidelines for the assessment of prostate alterations were designed for the assessment of prostate pathology. Published by the ESUR in 2012, PI-RADS v1 was based on the total score of different MRI sequences with subsequent calculation. PI-RADS v2 was published by the American College of Radiology in 2015 and featured...
متن کاملStandardized Reporting of Prostate MRI: Comparison of the Prostate Imaging Reporting and Data System (PI-RADS) Version 1 and Version 2
INTRODUCTION Objective of our study was to determine the agreement between version 1 (v1) and v2 of the Prostate Imaging Reporting and Data System (PI-RADS) for evaluation of multiparametric prostate MRI (mpMRI) and to compare their diagnostic accuracy, their inter-observer agreement and practicability. MATERIAL AND METHODS mpMRI including T2-weighted imaging, diffusion-weighted imaging (DWI)...
متن کاملProstate MRI based on PI-RADS version 2: how we review and report.
Prostate imaging and interpretation is based on prostate imaging reporting and data system version 2 (PI-RADS™ v2) providing clinical guidelines for multiparametric magnetic resonance imaging (mpMRI) of the prostate. PI-RADS™ v2 aims to promote global standardisation, to diminish variation in the acquisition, interpretation and reporting of prostate mpMRI examinations and to improve detection, ...
متن کاملProstate Imaging Reporting and Data System (PI-RADS), Version 2: A Critical Look.
OBJECTIVE The purpose of this article is to highlight the potential challenges associated with the Prostate Imaging Reporting and Data System, version 2 (PI-RADS v2), and to offer, when possible, suggestions and ideas for improvement. CONCLUSION PI-RADS v2 offers clear improvements to its earlier version and will greatly benefit the prostate MRI community. Nonetheless, caution remains on the ...