Factors affecting bronchodilator delivery in mechanically ventilated adults.
نویسندگان
چکیده
BACKGROUND Bronchodilators are increasingly being used in patients undergoing mechanical ventilation. There are multiple factors that affect bronchodilator delivery during mechanical ventilation. These factors can be classified into three categories: ventilator-related factors, circuit-related factors and device-related factors. AIMS The purpose of this paper is to review in depth each of the factors affecting bronchodilator delivery during mechanical ventilation. SEARCH STRATEGIES A literature search was undertaken using several databases including Cochrane, Pubmed, Medline, Cinahl and Science Direct. The literature search, although limited to the English language, covered materials from 1985 to May 2009. CONCLUSION Aerosolized bronchodilator delivery to mechanically ventilated patients is complex as a result of the multiple factors that affect the amount of aerosol deposited in the lower respiratory tract. When these factors are not carefully controlled and the optimum technique for aerosol delivery is not utilized, a greater proportion of the aerosol will deposit in the ventilator circuits and artificial airways decreasing the available dose to the patient. Attention to these factors and optimizing aerosol delivery techniques will help to reach therapeutic endpoints of bronchodilator therapy in patients receiving ventilatory support. RELEVANCE TO CLINICAL PRACTICE Bronchodilator delivery during mechanical ventilation is factor and technique dependent. A clear understanding of the factors affecting aerosol drug delivery during mechanical ventilation is very important in optimizing the efficiency of bronchodilator delivery in mechanically ventilated adults. Through the recommendations made in this paper, clinicians will be able to optimize both their technique and the therapeutic outcomes of aerosol drug delivery in patients receiving ventilator support.
منابع مشابه
Bronchodilator delivery with metered-dose inhalers in mechanically-ventilated patients.
Metered-dose inhalers (MDIs) provide several advantages over nebulizers, including ease of administration, decreased cost, reliability of dosing, and freedom from contamination. However, this method of aerosol delivery has been considered ineffective in mechanically-ventilated patients because most of the aerosol deposits in the endotracheal tube and ventilator circuit. A smaller amount of aero...
متن کاملInhalation therapy with metered-dose inhalers and dry powder inhalers in mechanically ventilated patients.
Pressurized metered-dose inhalers (pMDIs) are commonly employed for administering bronchodilator aerosols to mechanically ventilated patients. Although it is feasible to employ dry powder inhalers in ventilator circuits, the presence of humidity in the ventilator circuit could reduce their efficiency. A complex array of factors influence drug delivery from pMDIs during mechanical ventilation, a...
متن کاملInhaled bronchodilator administration during mechanical ventilation.
Inhaled bronchodilators are routinely administered to mechanically ventilated patients to relieve dyspnea and reverse bronchoconstriction. A lower percentage of the nominal dose reaches the lower respiratory tract in a mechanically ventilated patient than in a nonintubated subject, but attention to device selection, administration technique, dosing, and patient-ventilator interface can increase...
متن کاملClearing the mist from our eyes: bronchodilators, mechanical ventilation, new devices, locations, and what you should know about bias flow.
Patients with obstructive lung disease often present with life-threatening respiratory failure, confounded by severe air-flow limitation, dynamic hyperinflation, intrinsic PEEP, reduced pulmonary compliance, hypercarbia, and hemodynamic instability. Inhaled bronchodilators play a vital role in the care of such patients and are one of the most widely prescribed medications in the critical care s...
متن کاملBronchodilator therapy with metered-dose inhaler and spacer versus nebulizer in mechanically ventilated patients: comparison of magnitude and duration of response.
OBJECTIVE Four-hour comparison of the bronchodilator response of albuterol administered via metered-dose inhaler (MDI) with spacer versus small-volume nebulizer (SVN) to mechanically ventilated patients with chronic obstructive pulmonary disease (COPD). DESIGN Prospective randomized clinical trial. SETTING Medical intensive care unit in a university hospital. PATIENTS Thirteen mechanicall...
متن کاملذخیره در منابع من