Dosimetric Comparison of Fixed and Flexible Geometry ICRT Applicators in Patients Treated for Carcinoma Cervix
نویسندگان
چکیده
In intracavitary radiotherapy (ICRT) for cancer cervix, applicator geometry has the potential to impact the doses to organs at risk (OARs) and the coverage of the target volume. At our centre two Varian made Fletcher-style applicator sets, namely defined (fixed) geometry and flexible geometry, are used for ICRT. In the present work, the two types of applicators were compared dosimetrically as per the recommendations of the International Commission on Radiation Units and Measurements (ICRU-38) while delivering high dose rate brachytherapy. Twenty four patients who underwent ICRT were considered for this study. Radiographic method was used for treatment planning on Abacus planning system. ICRU-38 recommended parameters were estimated and compared. Flexible geometry applicator showed 8.8% and 16% higher bladder and rectum point doses as compared to the fixed geometry one but the difference was statistically not significant. The thickness of the pear-shaped isodose volume was larger for the flexible geometry implant also indicating towards higher doses to OARs. The higher bladder and rectum point doses in the case of flexible applicator will need to be validated by a larger data set.
منابع مشابه
Comparison of radiotherapy techniques to reduce hematologic toxicity in whole pelvic radiation therapy
Introduction: Concurrent chemoradiotherapy (CRT) is a standard treatment method for patients with carcinoma of cervix. Despite admirable therapeutic results, acute hematologic toxicity (HT) is common with this regimen. Many studies evaluate the relationship between the bone marrow dosimetric parameters and the severity of HT and result shown that the low dose of bone marrow wou...
متن کاملPostoperative adjuvant chemotherapy combined with intracavitary brachytherapy in early-stage cervical cancer patients with intermediate risk factors
OBJECTIVE To investigate the impact of postoperative adjuvant therapy on survival of patients with intermediate risk early-stage cervical squamous cell carcinoma. METHODS A total of 133 consecutive patients with intermediate risk early-stage cervical squamous cell carcinoma treated at Shandong Cancer Hospital and Institute from February 2010 to March 2014 were enrolled in our study. All patie...
متن کاملDeveloping a Verification and Training Phantom for Gynecological Brachytherapy System
Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
متن کاملComparative evaluation of two-dimensional radiography and three dimensional computed tomography based dose-volume parameters for high-dose-rate intracavitary brachytherapy of cervical cancer: a prospective study.
BACKGROUND Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. MATERIALS AND METHODS Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiothera...
متن کاملDosimetric Evaluation Study on Conventional and 3d Conformal Brachytherapy Treatment of Cervix Cancer
The purpose of this study was to compare International Commission on Radiation Units and Measurements (ICRU, report 38) reference points, used in conventional brachytherapy planning, with Computed Tomography (CT)-based volumetric calculations of radiation doses for target volumes and organs at risk in biopsy-proven cervix carcinoma patients. All patients underwent brachytherapy using CT-compati...
متن کامل