Comparative Simulation Study between Gate Firing Units for HVDC Rectifier Based on CIGRE Benchmark Model
نویسندگان
چکیده
A simulation study between the DQO gate firing unit (GFU) and a proposed GFU for high voltage direct current (HVDC) rectifier based on the CIGRE benchmark model in Matlab/Simulink is carried out. The proposed GFU does not use traditional phase lock loop (PLL) and offers structural simplicity, fast response and immunity to ac system voltage unbalance, harmonics, voltage sag, frequency jump and phase jump etc. Since there is no loop filter, no tuning issues are involved. Advantages of the proposed GFU are confirmed by extensive simulation results.
منابع مشابه
HVDC Transmission with STATCOM
Most of the HVDC power converters with thyristor valves are assembled in a converter Bridge of Six pulse configuration. Converter transformers with one DC side winding as an ungrounded star connection and the other a delta configuration. Comparative studies of the two systems of HVDC CIGRE model without STATCOM and with STATCOM were performed. In these case, the consideration was the converter ...
متن کاملReal-Time Simulation of VSC-based HVDC Systems using Rectification Capable Switching Function-Based 3-Level Inverter Models
This paper presents a simulation model of a 3-level Neutral-Point Clamped IGBT inverter bridge suitable for realtime simulation testing. The model is switching-function based but also works in rectifying mode. Because of the large number of individual switches that compose such an inverter, the switchingfunction approach produces exceptional computational speed gain when compared to piecewise t...
متن کاملPerformance Analysis of Hybrid HVDC Transmission Systems for Connecting Offshore Wind Farm to Onshore Grid
This paper presents the performance analysis of DFIG based off shore wind farm feeding to large power system through a hybrid HVDC link. The hybrid HVDC link consists of a line commutated converter based inverter and voltage source converter based rectifier. The active and reactive power of off shore station is controlled using voltage source converter based rectifier controller and the dc line...
متن کاملWind Farms with HVDC Delivery in Inertia Response and Load Frequency Control
This paper develops a coordination control strategy for wind farms with line commutated converter (LCC) based HVDC delivery to participate in inertia response and load frequency control. The coordination philosophy is to let the HVDC rectifier sense the grid frequency. If the grid frequency is too high or too low, active power flow through the HVDC link will be ramped down or up by introducing ...
متن کاملIntelligent Controller Based Improved Fault Ride-through Capability of Hvdc System Connected to Weak Ac Grid
In the paper, a novel HVDC transmission system operating with weak ac system has been modeled with speed and precision & analyses the control strategy & performance of system, which is controlled using fuzzy. The system can feed a weak or even dead network under fluctuations and big variations of the input power. The fuzzy logic-based control of the system helps to optimize the efficiency of th...