Axial nanometer distances measured by fluorescence lifetime imaging microscopy.
نویسندگان
چکیده
We present a novel fluorescence lifetime imaging microscopy technique to measure absolute positions of fluorescent molecules within 100 nm above a metalized surface based on distance-dependent fluorescence lifetime modulations. We apply this technique to fluorescently labeled microtubules as optical probes with various unlabeled proteins attached. By measuring the fluorescence lifetimes, we obtain the position of the microtubules and therefore determine the geometrical size of the attached proteins with nanometer precision.
منابع مشابه
Analysis of Multi - Channel Microscopy : Spectral Self - Interference , Multi - Detector Confocal and 4 Pi Systems
Fluorescence microscopy is an important and ubiquitous tool in biological imaging due to the high specificity with which fluorescent molecules can be attached to an organism and the subsequent nondestructive in-vivo imaging allowed. Focused-light microscopies allow three-dimensional fluorescence imaging but their resolution is restricted by diffraction. This effect is particularly limiting in t...
متن کاملThree-dimensional Localization of Nano-emitters with Nanometer-level Precision
We show nanometer-level localization accuracy of a single quantum-dot in three dimensions by self-interference and diffraction-pattern analysis. We believe that this approach has the capacity to push optical microscopy to the molecular level. ©2009 Optical Society of America OCIS codes: (180.2520) Fluorescence microscopy; (260.3160) Interference; (100.6640) Superresolution The use of fluorescen...
متن کاملNanometer axial resolution by three-dimensional supercritical angle fluorescence microscopy.
We report a noninvasive fluorescence microscopy method and demonstrate nanometer resolution along the optical axis. The technique is based on the influence of the microscope slide on the angular intensity distribution of fluorescence. Axial positions are determined by measuring the proportion of light emitted below the critical angle of total internal reflection, which behaves in a classical wa...
متن کاملProtein localization in living cells and tissues using FRET and FLIM.
Interacting proteins assemble into molecular machines that control cellular homeostasis in living cells. While the in vitro screening methods have the advantage of providing direct access to the genetic information encoding unknown protein partners, they do not allow direct access to interactions of these protein partners in their natural environment inside the living cell. Using wide-field, co...
متن کاملDiffraction phase and fluorescence microscopy.
We have developed diffraction phase and fluorescence (DPF) microscopy as a new technique for simultaneous quantitative phase imaging and epi-fluorescence investigation of live cells. The DPF instrument consists of an interference microscope, which is incorporated into a conventional inverted fluorescence microscope. The quantitative phase images are characterized by sub-nanometer optical path-l...