High Efficient Reconstruction of Single-shot T2 Mapping from OverLapping-Echo Detachment Planar Imaging Based on Deep Residual Network

نویسندگان

  • Congbo Cai
  • Yiqing Zeng
  • Chao Wang
  • Shuhui Cai
  • Jun Zhang
  • Zhong Chen
  • Xinghao Ding
  • Jianhui Zhong
چکیده

Purpose: An end-to-end deep convolutional neural network (CNN) based on deep residual network (ResNet) was proposed to efficiently reconstruct reliable T2 mapping from single-shot OverLapping-Echo Detachment (OLED) planar imaging. Methods: The training dataset was obtained from simulations carried out on SPROM software developed by our group. The relationship between the original OLED image containing two echo signals and the corresponded T2 mapping was learned by ResNet training. After the ResNet was trained, it was applied to reconstruct the T2 mapping from simulation and in vivo human brain data. Results: Though the ResNet was trained entirely on simulated data, the trained network was generalized well to real human brain data. The results from simulation and in vivo human brain experiments show that the proposed method significantly outperformed the echo-detachment-based method. Reliable T2 mapping was achieved within tens of milliseconds after the network had been trained while the echo-detachment-based OLED reconstruction method took minutes. Conclusion: The proposed method will greatly facilitate real-time dynamic and quantitative MR imaging via OLED sequence, and ResNet has the potential to reconstruct images from complex MRI sequence efficiently.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Rapid T2* mapping using interleaved echo planar imaging.

Magnetic resonance imaging methods that are sensitive to T2* are widely used in the study of blood oxygenation changes, most notably in functional studies of the brain. In these studies the signal intensity change in T2*-weighted imaging is related to the coupling of cerebral blood flow and metabolism. Rapid measurement of T2* itself would offer a valuable method to quantify blood oxygenation c...

متن کامل

Correction of geometric distortion in Propeller echo planar imaging using a modified reversed gradient approach.

OBJECTIVE This study investigates the application of a modified reversed gradient algorithm to the Propeller-EPI imaging method (periodically rotated overlapping parallel lines with enhanced reconstruction based on echo-planar imaging readout) for corrections of geometric distortions due to the EPI readout. MATERIALS AND METHODS Propeller-EPI acquisition was executed with 360-degree rotationa...

متن کامل

A modified EPI sequence for high-resolution imaging at ultra-short echo time.

A robust modification of echo-planar imaging dubbed double-shot echo-planar imaging with center-out trajectories and intrinsic navigation (DEPICTING) is proposed, which permits imaging at ultra-short echo time. The k-space data is sampled by two center-out trajectories with a minimal delay achieving a temporal efficiency similar to conventional single-shot echo-planar imaging. Intersegment phas...

متن کامل

Functional magnetic resonance imaging using PROPELLER-EPI.

Periodically rotated overlapping parallel lines with enhanced reconstruction-echo-planar imaging (PROPELLER-EPI) is a multishot technique that samples k-space by acquisition of narrow blades, which are subsequently rotated until the entire k-space is filled. It has the unique advantage that the center of k-space, and thus the area containing the majority of functional MRI signal changes, is sam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • CoRR

دوره abs/1708.05170  شماره 

صفحات  -

تاریخ انتشار 2017