Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans.

نویسندگان

  • P J Quigley
  • T Hinohara
  • H R Phillips
  • R H Peter
  • V S Behar
  • Y Kong
  • C A Simonton
  • J A Perez
  • R S Stack
چکیده

An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between two inflations by standard angioplasty catheters. Chest pain score, 12-lead electrocardiogram, heart rate, and mean aortic pressure were recorded before each inflation and at 1-minute intervals after inflation. Inflation duration during autoperfusion angioplasty (513 +/- 303 seconds) was longer than for the pre- (107 +/- 55 seconds, p = 0.0004) and post- (139 +/- 71 seconds, p = 0.0006) standard dilatations. The maximum ST-segment elevation and depression in any lead during autoperfusion angioplasty (0.3 +/- 0.5 and 0.6 +/- 0.8 mm) was significantly less than for the pre- (2.4 +/- 1.7 mm, p = 0.002 and 2.2 +/- 1.3 mm, p = 0.0004) or post- (1.9 +/- 1.3 mm, p = 0.002 and 1.6 +/- 1.3 mm, p = 0.018) standard dilatations at the same point in time. Maximal chest pain score during autoperfusion (3.2 +/- 3.5) was lower than for the pre- (6.1 +/- 2.1, p = 0.003) but not the post- (5.2 +/- 3.1, p = 0.07) standard angioplasty. All 11 patients underwent successful, uncomplicated procedures. We conclude that this autoperfusion catheter significantly reduces ischemic symptoms and signs during coronary angioplasty, allowing prolonged periods of balloon inflation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preservation of distal coronary perfusion during prolonged balloon inflation with an autoperfusion angioplasty catheter.

A newly designed balloon coronary angioplasty catheter that allows passive antegrade blood flow during balloon inflation (autoperfusion catheter) was compared with a standard balloon coronary angioplasty catheter. In a randomized sequence, inflations were performed for 3 min in the left circumflex coronary artery of 12 dogs with the standard catheter followed by the autoperfusion catheter or vi...

متن کامل

Extent of Electrocardiographic Ischemic Changes and Duration of Inflation With Standard and Autoperfusion Angioplasty SRI PBC SR

An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between ...

متن کامل

Extent of Electrocardiographic Ischemic Changes and Duration of Inflation With Standard and Autoperfusion Angioplasty SRI PBC SR 2 ST

An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between ...

متن کامل

Coronary artery dissection caused by exit of the guidewire through the distal perfusion sidehole of an auto-perfusion angioplasty balloon catheter.

A previously unrecognized cause of coronary artery dissection is reported. A 67-year-old woman underwent angioplasty of the right coronary artery using an autoperfusion balloon catheter. Dissection occurred because the balloon catheter was advanced while the guidewire exited from one of the distal perfusion sideholes.

متن کامل

Selective suction and pressure-regulated retroinfusion: an effective and safe approach to retrograde protection against myocardial ischemia in patients undergoing normal and high risk percutaneous transluminal coronary angioplasty.

OBJECTIVES We sought to study the safety, feasibility and efficacy of selective suction and pressure-regulated retroinfusion to protect against myocardial ischemia in patients undergoing normal risk and high risk balloon angioplasty. BACKGROUND In a pig model of acute myocardial ischemia it was previously shown that use of selective suction and pressure-regulated retroinfusion was able to sub...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 78 5 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1988