Chemiluminescence determination of sodium 2-mercaptoethane sulfonate by flow injection analysis using cerium(IV) sensitized by quinine.
نویسندگان
چکیده
A flow injection method with chemiluminescence (CL) detection is proposed for the determination of sodium 2-mercaptoethane sulfonate (MESNA), a drug often used to reduce the urotoxic effects of antineoplastic alkylating agents. The procedure is based on the reaction of the thiol with Ce(IV) in a sulfuric acid medium and measurement of the CL intensity produced by quinine used as a sensitizer. The optimum conditions for CL emission were investigated. Using the CL peak height as the analytical parameter, MESNA was determined over the concentration range 0.29-2.21 ng (1.97-9.85 mug.l(-1)) with a detection limit of 0.21 ng (1.38 mug.l(-1)) and a relative standard deviation (R.S.D.) of 4.1%. The method was applied satisfactorily to the determination of MESNA in pharmaceutical preparations with percentages of recovery between 94 and 105.
منابع مشابه
Terbium Sensitized Chemiluminescence Method for the Determination of Rabeprazole -Application to Pharmaceutical Analysis and Dissolution Studies
A simple and sensitive chemiluminescence-based method was established for the determination of rabeprazole.The proposed method was based on the enhancing effect of rabeprazole on Ce(IV)-Na2SO3 -Tb(III) chemiluminescence reaction. A possible mechanism was discussed for chemiluminescence system by studying UV-Vis, fluorescence and chemiluminescence spectra. The effects of va...
متن کاملFast determination of thiacloprid by photoinduced chemiluminescence.
A new and sensitive application of chemiluminescence detection has been developed for the determination of the pesticide thiacloprid in water. It was based on the on-line photoreaction of thiacloprid in a basic medium, with quinine acting as the sensitizer of the chemiluminescent response; cerium (IV) in sulfuric acid medium was used as the oxidant. High degrees of automation and reproducibilit...
متن کاملFlow-injection chemiluminometric analysis of some benzamides by their sensitizing effect on the cerium-sulphite reaction.
A simple, highly sensitive chemiluminescent method using flow injection is described for the determination of three substituted benzamides, namely: sulpiride, sultopride and tiapride. The method is based on the sensitizing effect of these drugs on the chemiluminometric oxidation of sulphite by cerium(IV). The different experimental parameters affecting the chemiluminescence intensity were caref...
متن کاملFlow-injection chemiluminometric determination of pioglitazone HCl by its sensitizing effect on the cerium-sulfite reaction.
A flow injection chemiluminescent (FI-CL) method was developed for the determination of pioglitazone HCl. It is based on the sensitizing effect of the drug on the oxidation reaction of sulfite with cerium(IV). The different experimental parameters affecting the chemiluminescence intensity, such as concentration of reagents and some physical parameters of the manifold, were carefully studied and...
متن کاملFlow-injection chemiluminescence and electrogenerated chemiluminescence determination of escitalopram oxalate in tablet form.
Rapid, simple and highly sensitive flow-injection (FI) chemiluminescence (CL) and flow-injection electrogenerated chemiluminescence (ECL) methods were developed for the determination of escitalopram oxalate (ESC), a selective serotonin reuptake inhibitor used as an antidepressant drug. The CL method was based on the CL reaction of ESC with acidic cerium(IV) and tris(2,2'-bipyridyl)ruthenium(II)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 51 6 شماره
صفحات -
تاریخ انتشار 2000