Evaluation of speech recognition in noise with cochlear implants and dynamic FM.

نویسندگان

  • Jace Wolfe
  • Erin C Schafer
  • Benjamin Heldner
  • Hans Mülder
  • Emily Ward
  • Brandon Vincent
چکیده

BACKGROUND Use of personal frequency-modulated (FM) systems significantly improves speech recognition in noise for users of cochlear implants (CIs). Previous studies have shown that the most appropriate gain setting on the FM receiver may vary based on the listening situation and the manufacturer of the CI system. Unlike traditional FM systems with fixed-gain settings, Dynamic FM automatically varies the gain of the FM receiver with changes in the ambient noise level. There are no published reports describing the benefits of Dynamic FM use for CI recipients or how Dynamic FM performance varies as a function of CI manufacturer. PURPOSE To evaluate speech recognition of Advanced Bionics Corporation or Cochlear Corporation CI recipients using Dynamic FM vs. a traditional FM system and to examine the effects of Autosensitivity on the FM performance of Cochlear Corporation recipients. RESEARCH DESIGN A two-group repeated-measures design. Participants were assigned to a group according to their type of CI. STUDY SAMPLE Twenty-five subjects, ranging in age from 8 to 82 years, met the inclusion criteria for one or more of the experiments. Thirteen subjects used Advanced Bionics Corporation, and 12 used Cochlear Corporation implants. INTERVENTION Speech recognition was assessed while subjects used traditional, fixed-gain FM systems and Dynamic FM systems. DATA COLLECTION AND ANALYSIS In Experiments 1 and 2, speech recognition was evaluated with a traditional, fixed-gain FM system and a Dynamic FM system using the Hearing in Noise Test sentences in quiet and in classroom noise. A repeated-measures analysis of variance (ANOVA) was used to evaluate effects of CI manufacturer (Advanced Bionics and Cochlear Corporation), type of FM system (traditional and dynamic), noise level, and use of Autosensitivity for users of Cochlear Corporation implants. Experiment 3 determined the effects of Autosensitivity on speech recognition of Cochlear Corporation implant recipients when listening through the speech processor microphone with the FM system muted. A repeated-measures ANOVA was used to examine the effects of signal-to-noise ratio and Autosensitivity. RESULTS In Experiment 1, use of Dynamic FM resulted in better speech recognition in noise for Advanced Bionics recipients relative to traditional FM at noise levels of 65, 70, and 75 dB SPL. Advanced Bionics recipients obtained better speech recognition in noise with FM use when compared to Cochlear Corporation recipients. When Autosensitivity was enabled in Experiment 2, the performance of Cochlear Corporation recipients was equivalent to that of Advanced Bionics recipients, and Dynamic FM was significantly better than traditional FM. Results of Experiment 3 indicate that use of Autosensitivity improves speech recognition in noise of signals directed to the speech processor relative to no Autosensitivity. CONCLUSIONS Dynamic FM should be considered for use with persons with CIs to improve speech recognition in noise. At default CI settings, FM performance is better for Advanced Bionics recipients when compared to Cochlear Corporation recipients, but use of Autosensitivity by Cochlear Corporation users results in equivalent group performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Speech recognition abilities of adults using cochlear implants with FM systems.

Speech recognition was evaluated for ten adults with normal hearing and eight adults with Nucleus cochlear implants (CIs) at several different signal-to-noise ratios (SNRs) and with three frequency modulated (FM) system arrangements: desktop, body worn, and miniature direct connect. Participants were asked to repeat Hearing in Noise Test (HINT) sentences presented with speech noise in a classro...

متن کامل

Correlation between Auditory Spectral Resolution and Speech Perception in Children with Cochlear Implants

Background: Variability in speech performance is a major concern for children with cochlear implants (CIs). Spectral resolution is an important acoustic component in speech perception. Considerable variability and limitations of spectral resolution in children with CIs may lead to individual differences in speech performance. The aim of this study was to assess the correlation between auditory ...

متن کامل

Contribution of frequency modulation to speech recognition in noise.

Cochlear implants allow most patients with profound deafness to successfully communicate under optimal listening conditions. However, the amplitude modulation (AM) information provided by most implants is not sufficient for speech recognition in realistic settings where noise is typically present. This study added slowly varying frequency modulation (FM) to the existing algorithm of an implant ...

متن کامل

Speech Recognition in noise in children with cochlear implants while listening in bilateral, bimodal, and FM-system arrangements.

PURPOSE Speech recognition performance in noise was examined in children with cochlear implants (CIs) when using (a) a second CI (bilateral group), (b) a hearing aid (HA) on the nonimplant ear (bimodal group), and (c) a frequency modulation (FM) system on 1 or both sides. METHOD While always maintaining use of the first CI, 2 groups participated in 6 conditions each using various listening ar...

متن کامل

Auditory-Visual Speech Recognition with Amplitude and Frequency Modulations

A recent study by Zeng et al (2005) [PNAS, 102, 2293-2298] demonstrated the importance of FM cues for auditory speech identification in a competing noise environment. The current speech identification study investigated this finding for both an Auditory Only (AO) and an Auditory-Visual (AV) speech in noise identification task. The results demonstrated an FM advantage (compared to AM only) for b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 20 7  شماره 

صفحات  -

تاریخ انتشار 2009