Age-dependent normal values of T2* and T2' in brain parenchyma.

نویسندگان

  • S Siemonsen
  • J Finsterbusch
  • J Matschke
  • A Lorenzen
  • X-Q Ding
  • J Fiehler
چکیده

BACKGROUND AND PURPOSE Physiologic age-related T2* and T2' values are required as reference for comparison with disease-related deviations. In our study, T2* and T2' values (T2 values as control) were determined with MR imaging in healthy subjects to determine standard values and investigate age-related changes. MATERIALS AND METHODS Data of 50 patients without intraparenchymal pathology and 10 acute stroke patients who underwent MR imaging including a T2 and T2* sequence with 3 echotimes were included. After calculation of T2*, T2', and T2 maps, the values of gray matter (GM) and white matter (WM) for each hemisphere were measured in 6 distinct regions of interest (ROIs). RESULTS There was a negative correlation between age and T2* values in the caudate nucleus (r = -0.34 Pearson correlation; P = .001) and lentiform nucleus (r = -0.67; P = .001) and a positive correlation in the occipital (r = 0.41; P = .001) and subcortical (r = 0.45; P = .001) WM. An age dependency for T2' values was only found for the caudate (r = -0.35; P = .001) and lentiform nucleus (r = -0.69; P = .001). T2' values in acute stroke were lower than normal in all patients with stroke. CONCLUSION Decrease in T2' and T2* values in GM and increase of T2* values in WM correlate with the progress of brain aging. Explanations for decreasing T2' and T2* values include iron deposition in the caudate and lentiform nucleus. In contrast to T2* values, there is no association of T2' values with the degree of leukoaraiosis. These age-dependent values can be used as a reference in neurovascular diseases and for the discussion of functional MR imaging data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

The Assessment of Structural Changes in MS Plaques and Normal Appearing White Matter Using Quantitative Magnetization Transfer Imaging (MTI)

Introduction: Multiple sclerosis (MS) is a demyelinating disease of the central nervous system (CNS), affecting mostly young people at a mean age of 30 years. Magnetic resonance imaging (MRI) is one of the most specific and sensitive methods in diagnosing and detecting the evolution of multiple sclerosis disease. But it does not have the ability to differentiate between distinct histopathologic...

متن کامل

T2 relaxation values in the developing preterm brain.

BACKGROUND AND PURPOSE MR imaging is increasingly used to assess maturation and disease in the preterm brain. Knowledge of the changes in T2 values with increasing postmenstrual age (PMA) will aid image interpretation and help in the objective assessment of maturation and disease of the brain in infants. The aim of this study was to obtain T2 values in the preterm brain from 25 weeks' gestation...

متن کامل

Normal regional brain iron concentration in restless legs syndrome measured by MRI

Using a T2* gradient echo magnetic resonance imaging (MRI) sequence, regional T2 signal intensity (SI) values, a surrogate marker for T2 values, were determined in 12 regions of interest (substantia nigra, pallidum, caudate head, thalamus, occipital white matter, and frontal white matter bilaterally) and in two reference regions (cerebrospinal fluid and bone) in 12 patients suffering from moder...

متن کامل

Age and sex corrected normal reference values of T1, T2 T2* and ECV in healthy subjects at 3T CMR

BACKGROUND Myocardial T1, T2 and T2* imaging techniques become increasingly used in clinical practice. While normal values for T1, T2 and T2* times are well established for 1.5 Tesla (T) cardiovascular magnetic resonance (CMR), data for 3T remain scarce. Therefore we sought to determine normal reference values relative to gender and age and day to day reproducibility for native T1, T2, T2* mapp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2008