Endoscopic management of transnasal intracranial penetrating foreign bodies.
نویسندگان
چکیده
As experience with endoscopic sinus surgery has grown, so have its extended applications. Endoscopic management of transnasal intracranial foreign bodies can be successfully performed in selected patients and yields an improved cosmetic outcome and a decreased risk in complications. The patient was a 21 year old male who was driving intoxicated and sustained a motor vehicle accident. Patient was ejected from his vehicle and launched toward a tree. Patient presented to our institution with a tree branch which had entered the left aspect of his oral cavity piercing through his gingival labial sulcus, traveling into his left nasal cavity, penetrating through the septum into the right nasal cavity, traveling intracranially and piercing white matter. There was no evidence of a CSF leak at time of presentation.
منابع مشابه
Endoscopic Removal of a Bullet Penetrating the Middle Cranial Fossa
Reports of intracranial retained foreign bodies are relatively rare in the literature. Such objects can cause numerous complications requiring removal, such as infection, persistent cerebrospinal fluid (CSF) leak, or new-onset seizures. The transnasal endoscopic approach provides an excellent alternative to craniotomy for repairing middle cranial fossa (MCF) defects. We describe a case of a 57-...
متن کاملTransnasal penetrating intracranial injury with a chopstick.
We report the first case of a transnasal penetrating intracranial injury in Hong Kong by a chopstick. A 49-year-old man attempted suicide by inserting a wooden chopstick into his left nose and then pulled it out. The chopstick caused a transnasal penetrating brain injury, confirmed by contrast magnetic resonance imaging of the brain. He was managed conservatively. Later he developed meningitis ...
متن کاملEndoscopic transnasal removal of an intraconal foreign body using an image-guided surgical system.
Foreign bodies lodged in the intraconal space of the orbit pose a surgical challenge due to its deep location behind the globe. Image-guided endoscopic transnasal surgery facilitates the localization of the metallic foreign bodies and enables its safe removal with minimal surrounding tissue damage and optic nerve injury.
متن کاملTransnasal, Transethmoidal Endoscopic Removal of a Foreign Body in the Medial Extraconal Orbital Space
Intraorbital foreign bodies are located within the orbit but outside the ocular globe. Though not uncommon, removal of these objects poses a challenge for surgeons. External approaches have been the most frequently used but are associated with increased complications and morbidity. An endoscopic endonasal approach can be an appropriate and less complicated technique in these cases. We report a ...
متن کاملAn Organic Intravesical Foreign Body Caused by Penetrating Trauma that was Missed during Initial Management
We report a case of an intravesical foreign body that was incompletely removed endoscopically and that defied diagnosis with current diagnostic tools. A 65-year-old man visited Korea University Anam Hospital complaining of dysuria and a sensation of residual urine. His medical history included an intravesical foreign body caused by penetrating trauma, and he had undergone endoscopic removal of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Laryngoscope
دوره 120 Suppl 4 شماره
صفحات -
تاریخ انتشار 2010