Effect of Reinforcing Bar Contamination on Steel-Concrete Bond During Concrete Construction

نویسندگان

  • Lawrence H. Taber
  • David N. Richardson
چکیده

Synopsis: During concrete construction, form oil, bond breaker, concrete splatter and other types of contaminants often contaminate reinforcement. Current specifications and quality control measures require the removal and clean up of these contaminants before the placement of concrete due to a concern of a reduction in bonding capacity. This is costly, labor intensive, and may not be necessary. Currently, there is limited research on the effect of reinforcing bar contamination on the bond between the deformed steel reinforcing bar and concrete. Because of this lack of data, specifications are conservative and require the removal of the contaminant. Inspectors often cite ACI 301-96, Standard Specifications for Structural Concrete, which states, “When concrete is placed, all reinforcement shall be free of materials deleterious to bond.” If it could be conclusively proven that this level of care is unnecessary, the construction industry would benefit greatly. To address the effects of contaminants on bond characteristics of deformed steel reinforcing bars, a preliminary study was completed at the University of Missouri-Rolla. The research program focused on three contaminants often seen during construction: form oil, bond breaker and concrete splatter. Other variables included size of reinforcing bar, strength of concrete and epoxy versus uncoated reinforcing bar. This paper will provide the experimental program and test procedures as well as the test results and observations. The results reveal that in the majority of situations tested, the ultimate bond stress was not significantly affected by the three contaminants tested. In some cases, the bond breaker and form oil affected the smaller epoxy coated bars, while the effect of concrete splatter was insignificant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Impressed Current on Bond Strength Between Steel Rebar and Concrete

The deterioration of bond strength between reinforcing steel and concrete as a result of impressed cathodic current with respect to the exposure time was investigated. A current in the magnitude of 3ma/ft2 (based on reinforcing rebar area) was used for a period of five years. Chemical analyses for sodium (Na+), potassium (K+) and chloride (Cl-) ions in concrete cylinders were performed as a fun...

متن کامل

An Experimental Study on Effect of Steel Corrosion on the Bond–Slip Performance of Reinforced Concrete

This paper studied the effects of reinforcement corrosion on bond performance between rebar and concrete. Tests were carried out to evaluate the degradation of bond between reinforcing steel and concrete for different corrosion levels of reinforcing steel. A series of 20 specimens of different concrete strength with various reinforcing steel corrosion levels were designed and manufactured. Each...

متن کامل

A Study on the Bond Strength between High Performance Concrete and Reinforcing Bar

As a preliminary study for the erection of floating structures using high performance concrete, this paper examines the bond characteristics between concrete and the reinforcing bar. Since the floating structure is constructed in aquatic environment, corrosion of the reinforcing steel is likely to develop more prematurely than in onshore structure in case of concrete cracking. A solution to thi...

متن کامل

Bond of High Strength Concrete with High Strength Reinforcing Steel

This paper presents a study about the bond of high strength concrete with high strength steel. Fourteen pull out tests were carried out to determine the bond. The concrete strength was about 70 MPa and the steel was a 500 MPa grade. Bar diameters used were 12, 16, 20, 25, 28, 32 and 36 mm. In order to investigate the effect of cover, each test was done twice, once in a 240 mm diameter concrete ...

متن کامل

Effect of the Concrete Strength on the Concrete-Steel Bond in Concrete Filled Steel Tubes

In this study, the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bond carrying capacity. Four different concrete mixes were used in preparing the specimens. The steel tubes were w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003