Validation of Noninvasive Measurement of Cardiac Output Using Inert Gas Rebreathing in a Cohort of Patients With Heart Failure and Reduced Ejection Fraction.
نویسندگان
چکیده
BACKGROUND Cardiac output (CO) is a key indicator of cardiac function in patients with heart failure. No completely accurate method is available for measuring CO in all patients. The objective of this study was to validate CO measurement using the inert gas rebreathing (IGR) method against other noninvasive and invasive methods of CO quantification in a cohort of patients with heart failure and reduced ejection fraction. METHODS AND RESULTS The study included 97 patients with heart failure and reduced ejection fraction (age 42±15.5 years; 64 patients (65.9%) had idiopathic dilated cardiomyopathy and 21 patients (21.6%) had ischemic heart disease). Median left ventricle ejection fraction was 24% (10%-36%). Patients with atrial fibrillation were excluded. CO was measured using 4 methods (IGR, cardiac magnetic resonance imaging, cardiac catheterization, and echocardiography) and indexed to body surface area (cardiac index [CI]). All studies were performed within 48 hours. Median CI measured by IGR was 1.75, by cardiac magnetic resonance imaging was 1.82, by cardiac catheterization was 1.65, and by echo was 1.7 L·min-1·m-2. There were significant modest linear correlations between IGR-derived CI and cardiac magnetic resonance imaging-derived CI (r=0.7; P<0.001), as well as cardiac catheterization-derived CI (r=0.6; P<0.001). Using Bland-Altman analysis, the agreement between the IGR method and the other methods was as good as the agreement between any 2 other methods with each other. CONCLUSIONS The IGR method is a simple, accurate, and reproducible noninvasive method for quantification of CO in patients with advanced heart failure. The prognostic value of this simple measurement needs to be studied prospectively.
منابع مشابه
Peak cardiac power output, measured noninvasively, is a powerful predictor of outcome in chronic heart failure.
BACKGROUND The cardiac output (CO) response to exercise and other invasively derived hemodynamic variables has been variably described to provide better prognostication than peak V(O(2)) in patients with chronic heart failure. Using noninvasive measurements of CO during exercise, we compared the prognostic value of peak CO and cardiac power to peak V(O(2)) in chronic heart failure patients. M...
متن کاملThe reliability of noninvasive cardiac output measurement using the inert gas rebreathing method in patients with advanced heart failure.
BACKGROUND Impaired cardiac output (CO) is a key element of heart failure (HF). So far, there has been no simple, reliable, inexpensive and non-invasive CO measurement method feasible for clinical practice. Not a single diagnostic test has been elaborated to diagnose and monitor HF. The aim of the study was the evaluation of the reliability of a new, non-invasive CO measurement device utilizing...
متن کاملEvaluation of heart disease in patients with beta-thalessemia major referred to Shahid Madanni Hospital in Khorram Abad in 2003
Background: Patients with beta-thalessemia major present with severe anemia and need continous transfusion therapy. An important complication of beta-thalessemia major is iron deposition in cardiac tissue, resulting in fibrosis and dysfunction. Cardiac involvement is the major cause of death in beta-thalessemia major. The purpose of this study was to assess cardiac disease patients with bet...
متن کاملExercise performance, haemodynamics, and respiratory pattern do not identify heart failure patients who end exercise with dyspnoea from those with fatigue†
AIMS The two main symptoms referred by chronic heart failure (HF) patients as the causes of exercise termination during maximal cardiopulmonary exercise testing (CPET) are muscular fatigue and dyspnoea. So far, a physiological explanation why some HF patients end exercise because of dyspnoea and others because of fatigue is not available. We assessed whether patients referring dyspnoea or muscu...
متن کاملEvaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics
Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria. Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Heart failure
دوره 10 3 شماره
صفحات -
تاریخ انتشار 2017