Development of a small and flexible sensor-based respirometer for real-time determination of respiration rate, respiratory quotient and low O2 limit of fresh produce

نویسندگان

  • Pramod V. Mahajan
  • Alexandru Luca
  • Merete Edelenbos
چکیده

Information on the respiration rate and the low O2 limit (LOL) is important for optimization of packaging and storage systems for fresh fruit and vegetables. In this study, a small and flexible sensor-based respirometer was developed for real-time determination of the respiration rate, respiratory quotient (RQ), and LOL of fresh produce. The respirometer consisted of a wide mouth 1-L glass jar with a screw-type metal lid and an electrochemical and an infra-red sensor mounted directly on the lid of the glass jar to take continuous and non-invasive measurements of the O2 and CO2 contents. Data from the respirometer was compared with data obtained from two fluorescence-based spot sensors (OpTech and PreSens) and a headspace gas analyzer (CheckMate). A test with strawberry showed that similar respiration rates (14.1–16.2 mL O2 kg 1 h 1 and 13.4–16.4 mL CO2 kg 1 h 1 at 10 C) were obtained with all instruments. Further on, a Savitzky–Golay smoothing filter was implemented on the data from the respirometer to estimate the real-time respiration rate. The result showed that the respiration rate could be acquired in 2–3 h after filling of the respirometer or even after 1 h if the produce was equilibrated to the target storage temperature before the measurements. Detailed information on the respiration rate of wild rocket, strawberry, and carrot showed that the respiration rate decreased with time as the O2 content decreased; however, the RQ remained almost constant throughout storage until the LOL was reached. Information on the RQ and the LOL value is rare in the literature; however, the RQ and the LOL could easily be determined by the use of the respirometer. The RQ was 1.0, 1.0–1.5, and 0.5 for wild rocket, strawberry, and carrot, respectively, during storage under an O2 content above >2.0 kPa. As the O2 content dropped to 0.5, 1.0 and 2.0 kPa O2, for wild rocket, strawberry, and carrot, respectively, the RQ values increased sharply. The described respirometer made it easy to analyze the impact of a dynamic temperature and O2 content on the respiration rate, the RQ, and the LOL as handling was limited and real-time data could be obtained. With such detailed information, a knowledge-intensive design of packaging and storage systems for fresh horticultural produce is enabled. 2016 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of breast milk odor on concentration percentage of oxygen saturation and respiratory rate in premature infants

Background: establishing a regular respiratory condition in the infants is one of the basic considerations in NICU.  Newborns show noticeable breath alterations in response to even low concentrations of some fragrance. Aim: determining the effect of breast milk odor on oxygen saturation and respiratory rate in premature infants. Methods: In this four-group randomized clinical trial, 180 prematu...

متن کامل

Modelling respiration rate of fresh fruits and vegetables for modified atmosphere packages: a review

Respiration rate and gas exchange through the package material are the processes involved in creating a modified atmosphere inside a package that will extend shelf life of fresh fruits and vegetables. Thus, modelling respiration rate of the selected produce is crucial to the design of a successful modified atmosphere packaging (MAP) system. In this paper, general aspects of the respiration proc...

متن کامل

Low Cost UAV-based Remote Sensing for Autonomous Wildlife Monitoring

In recent years, developments in unmanned aerial vehicles, lightweight on-board computers, and low-cost thermal imaging sensors offer a new opportunity for wildlife monitoring. In contrast with traditional methods now surveying endangered species to obtain population and location has become more cost-effective and least time-consuming. In this paper, a low-cost UAV-based remote sensing platform...

متن کامل

Real Time Calibration of Strap-down Three-Axis-Magnetometer for Attitude Estimation

Three-axis-magnetometers (TAMs) are widely utilized as a key component of attitude determination subsystems and as such are considered the corner stone of navigation for low Earth orbiting (LEO) space systems. Precise geomagnetic-based navigation demands accurate calibration of the magnetometers. In this regard, a complete online calibration process of TAM is developed in the current research t...

متن کامل

Determination of trace amounts of Ag (I) in waste water samples by a novel potentiometric sensor based on perphenazine as an ionophore

Background and Objective: Silver is a toxic heavy metal that is used in various industries and has adverse effects on both human health and the environment. In this respect its determination with sensitive and economic analytical methods is of great importance. Materials and Methods: In this research, a novel ion selective electrode based on perphenazine as an ionophore was developed for deter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computers and Electronics in Agriculture

دوره 121  شماره 

صفحات  -

تاریخ انتشار 2016