A proposed in-vessel calibration light source for the Joint European Torus.

نویسندگان

  • T M Biewer
  • D L Hillis
  • M F Stamp
  • K-D Zastrow
چکیده

An in-vessel calibration light source (ICLS) is proposed for use during extended shutdown periods of the Joint European Torus (JET). The ICLS is primarily a 12 in. integrating sphere (4 in. opening) with four lamps (of known radiance), which can be positioned inside the JET vacuum vessel via the remote handling arm during interventions in the JET operating schedule. This will facilitate the in situ calibration of optical diagnostics, which rely on absolute light intensity measurements currently made when the diagnostics are removed from JET. The ICLS could ultimately reduce/remove the mechanical stresses associated with the repositioning of diagnostics for calibration purposes. At least 10 diagnostic systems (approximately 20 diagnostic subsystems) could benefit from the ICLS; in some instances the ICLS provides the only viable absolute-calibration strategy. Moreover, the ICLS will be a broad-spectrum white light source, enabling intensity calibrations at all visible wavelengths. A secondary benefit of the ICLS is in its use as an illumination source for making measurements of the reflectance (over a broad spectral range and at multiple angles) from the tiles lining the JET vacuum vessel. During the ITER-like wall intervention new Be, C, and W tiles will be installed in JET and their reflectance measured. Measurements made in subsequent JET interventions will provide data on the effect of high-temperature plasma operation on the reflectance of these tiles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of an in-vessel calibration light source for JET.

An in-vessel calibration light source (ICLS) has been implemented for remote use during extended shutdown periods of the Joint European Torus (JET). The ICLS facilitated the in situ calibration of optical diagnostics, which previously were performed when the diagnostics were removed from JET. Since the ICLS is used to calibrate diagnostics over th...

متن کامل

Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...

متن کامل

Correction of the spectral calibration of the Joint European Torus core light detecting and ranging Thomson scattering diagnostic using ray tracing.

This work isolated the cause of the observed discrepancy between the electron temperature (T(e)) measurements before and after the JET Core LIDAR Thomson Scattering (TS) diagnostic was upgraded. In the upgrade process, stray light filters positioned just before the detectors were removed from the system. Modelling showed that the shift imposed on the stray light filters transmission functions d...

متن کامل

Identification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST).

The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnost...

متن کامل

A Statistical Study of two Diffusion Processes on Torus and Their Applications

Diffusion Processes such as Brownian motions and Ornstein-Uhlenbeck processes are the classes of stochastic processes that have been investigated by researchers in various disciplines including biological sciences. It is usually assumed that the outcomes of these processes are laid on the Euclidean spaces. However, some data in physical, chemical and biological phenomena indicate that they cann...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 79 10  شماره 

صفحات  -

تاریخ انتشار 2008