Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas.

نویسندگان

  • G A Eiceman
  • E V Krylov
  • N S Krylova
  • E G Nazarov
  • R A Miller
چکیده

Differential mobility spectrometry (DMS) of nitro-organic explosives and related compounds exhibited the expected product ions of M- or M x NO2- from atmospheric pressure chemical ionization reactions in purified air at 100 degrees C. Peaks in the differential mobility spectra for these ions were confined to a narrow range of compensation voltages between -1 to +3 V which arose through a low dependence of mobility for the ions in electric fields at E/N values between 0 and 120 Td (1 Td = 10(-17) V cm2). The field dependence of ions, described as an alpha parameter, ranged from -0.005 to 0.02 at a separation field of 100 Td. The alpha parameter could be controlled through the addition of organic vapors into the drift gas and was increased to 0.08-0.24 with 1000 ppm of methylene chloride in the drift gas. This modification of the drift gas resulted in compensation voltages of +3 to +21 V for peaks. The improved separation of peaks was consistent with a model of ion characterization by DeltaK or Kl - Kh, where Kl is the mobility coefficient of ions clustered with vapor neutrals during the low-field portion of the separation field waveform and Kh is for the same core ion when heated and declustered during the high-field portion of waveform.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...

متن کامل

Development of mass spectrometric methods for the quantitation of drugs of abuse and therapeutic drugs (DAT/TDM) in clinical samples

This study focuses on the quantitative analysis of the cardiac glycosidedrug digitoxin and its three main metabolites digitoxigenin-bisdigitoxose, digitoxigenin-monodigitoxose, and digitoxigenin using electrospray ionization-differential ion mobilityspectrometry-tandem mass spectrometry (ESI-DMS-MS/MS). Despite large molecularweight differences, gas-phase separation of the four ...

متن کامل

Using different drift gases to change separation factors (alpha) in ion mobility spectrometry

The use of different drift gases to alter separation factors (alpha) in ion mobility spectrometry has been demonstrated. The mobility of a series of low molecular weight compounds and three small peptides was determined in four different drift gases. The drift gases chosen were helium, argon, nitrogen, and carbon dioxide. These drift gases provide a range of polarizabilities and molecular weigh...

متن کامل

Analysis of heterogeneous uptake by nanoparticles via differential mobility analysis-drift tube ion mobility spectrometry.

Improved methods are needed to study sorption of vapor molecules by particles in the gas phase (heterogeneous uptake), which is an important process in both natural and engineered environments. Here, a new measurement system, composed of a differential mobility analyzer (DMA) and drift tube ion mobility spectrometer (DTIMS) in series, is used to examine the heterogeneous uptake of water vapor b...

متن کامل

Selective detection of alkanolamine vapors by ion mobility spectrometry with ketone reagent gases.

The ion mobility (IMS) spectra of the alkanolamines, monoethanolamine (MEA), 3-amino-1-propanol (PRA), 4-amino-1-butanol (BUA), and 5-amino-1-pentanol (PEA) with acetone and 4-heptanone reagent gases have been measured using a hand-held spectrometer. Monomer and dimer peak patterns were observed for all the alkanolamines with acetone reagent gas. Drift times of monomer and dimer ion clusters fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 76 17  شماره 

صفحات  -

تاریخ انتشار 2004