In vivo detection of Serine in Human Brain by Constant-TE Difference Editing at 3T
نویسندگان
چکیده
INTRODUCTION Serine (Ser) is an endogenous amino acid in brain which functions as a co-agonist with glutamate at the NMDA receptor. In disorders of cognition, especially psychosis, alterations in glutamate transmission have been found, possibly including serine signaling [1]. Noninvasive measure of Ser in brain could be pivotal in defining regional tissue pathology. Ser has three coupled resonances at 3.98, 3.96, and 3.83 ppm [2]. Ser is difficult to measure due to its relatively low concentration (~0.5 mM) and the spectral overlap with the creatine (Cr) 3.92 ppm resonance. Following the first attempt to detect Ser (4T) [3], measurement of Ser by constant-TE triple-refocusing difference editing at 7T was reported recently [4]. Here, we have exploited this editing method for measurement of Ser at 3T. A preliminary in vivo result from a healthy volunteer is presented.
منابع مشابه
Constant-TE difference editing of serine at 3T: Simulation and phantom Study
INTRODUCTION Activation of the N-methyl-D-aspartate (NMDA) receptor requires both glutamate binding and binding of an endogenous co-agonist at its glycine site. Accumulating evidence suggests that serine (Ser) is a potent agonist for the NMDA-glycine site [1]. Noninvasive measurements of Ser levels in human brain could therefore be important, particularly for the study of schizophrenia and its ...
متن کاملIn-Vivo Measurement of Serine in Human Brain by Constant-TE PRESS Difference Editing at 7.0 Tesla
INTRODUCTION: Serine (Ser), a co-agonist at N-methyl-D-aspartate receptors, has three coupled spins resonating at 3.98, 3.94 and 3.83 ppm [1]. Because of its low concentration (~0.5 mM) and the overlap with primarily the creatine (Cr) 3.92 ppm singlet, detection of Ser in human brain by H-MRS remains as a challenge. A spectrally-selective refocusing approach, that is the first attempt to measur...
متن کاملComparison of 1.5T and 3T 1H MR Spectroscopy for Human Brain Tumors
OBJECTIVE We wanted to estimate the practical improvements of 3T proton MR spectroscopy ((1)H MRS) as compared with 1.5T (1)H MRS for the evaluation of human brain tumors. MATERIALS AND METHODS Single voxel (1)H MRS was performed at both 1.5T and 3T in 13 patients suffering with brain tumors. Using the same data acquisition parameters at both field strengths, the (1)H MRS spectra were obtaine...
متن کاملGABA editing at 3T with Macromolecule Suppression: MEGA-SPECIAL
Introduction. One commonly used method for in-vivo magnetic resonance spectroscopy (MRS) detection of γ-aminobutyric acid (GABA) is the MEGA-PRESS technique [1], which enables direct observation of the GABA resonance at 3.02 ppm. Unfortunately, direct quantification of GABA using MEGA-PRESS is complicated by co-editing of macromolecule (MM) signals, which also resonate at 3.02 ppm [2]. Two meth...
متن کاملDetection of Resolved Glutamate and/or Glutamine Using Optimized STEAM at 3T – A Verification Study by Phantom Experiments
designed in [2] for unobstructed Glu and Gln detection with chosen (TE, TM) regions in white boxes for phantom experiments. Fig. 2. In vitro STEAM spectra of Glu and Gln acquired at (72ms, 06 ms) and (84 ms, 58 ms) at 3T and multiplied with a filter to render them representative of typical in vivo line widths. Fig. 3. In vivo STEAM spectra acquired from a voxel including the ACC of a healthy vo...