Barium dithionate as an EPR dosemeter.

نویسندگان

  • M P Baran
  • O A Bugay
  • S P Kolesnik
  • V M Maksimenko
  • V V Teslenko
  • T L Petrenko
  • M F Desrosiers
چکیده

Electron paramagnetic resonance (EPR) dosimetry is growing in popularity and this success has encouraged the search for other dosimetric materials. Previous studies of gamma-irradiated barium dithionate (BaS(2)O(6) x 2H(2)O) have shown promise for its use as a radiation dosemeter. This work studies in greater detail several essential attributes of the system. Special attention has been directed to the study of EPR response dependences on microwave power, irradiation temperature, minimum detectable dose and post-irradiation stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ammonium dithionate- a new material for highly sensitive EPR dosimetry.

Polycrystalline ammonium dithionate has been examined for its radiation response in the low dose range (<5Gy) using EPR technique. The SO(3)(-) radical ion was detected as a single EPR line with a peak-to-peak derivative width of ca. 0.44mT in irradiated samples and its intensity was found to vary linearly with dose. At equal and moderate settings of microwave power and modulation amplitude amm...

متن کامل

Potassium dithionate EPR dosimetry for determination of absorbed dose and LET distributions in different radiation qualities

Potassium dithionate EPR dosimetry for determination of absorbed dose and LET distributions in different radiation qualities. Abstract With an increasing interest in using protons and light ions for radiation therapy there is a need for possibilities to simultaneously determine both absorbed dose (D) and linear energy transfer, LET, (LΔ). Potassium dithionate (K2S2O6) tablets were irradiated in...

متن کامل

High-resolution mapping of 1D and 2D dose distributions using X-band electron paramagnetic resonance imaging.

Electron paramagnetic resonance imaging (EPRI) was performed to visualise 2D dose distributions of homogenously irradiated potassium dithionate tablets and to demonstrate determination of 1D dose profiles along the height of the tablets. Mathematical correction was applied for each relative dose profile in order to take into account the inhomogeneous response of the resonator using X-band EPRI....

متن کامل

EPR imaging of dose distributions aiming at applications in radiation therapy.

A one-dimensional electron paramagnetic resonance (EPR) imaging method for visualisation of dose distributions in photon fields has been developed. Pressed pellets of potassium dithionate were homogeneously irradiated in a (60)Co radiation field to 600 Gy. The EPR analysis was performed with an X-Band (9.6 GHz) Bruker E540 EPR and EPR imaging spectrometer equipped with an E540 GC2X two-axis X-b...

متن کامل

Electronic Structure Investigation of Octahedral Complex and Nano ring by NBO Analysis: An EPR Study

To calculation non-bonded interaction of the [CoCl6]3- complex embedded in nano ring, we focus on the single wall boron-nitride B18N18 nano ring. Thus, the geometry of B18N18 nano ring has been optimized by B3LYP method with EPR-II (Electron paramagnetic resonance) basis set and geometry of the [CoCl6]3- complex has been optimized at B3LYP method with Aldrich’s VTZ basis set and Stuttgart RSC 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 120 1-4  شماره 

صفحات  -

تاریخ انتشار 2006