Midterm results of the Ross procedure preserving the patient's aortic root.

نویسندگان

  • Hans- H Sievers
  • Gerlinde Dahmen
  • Bernhard Graf
  • Ulrich Stierle
  • Andreas Ziegler
  • Claudia Schmidtke
چکیده

BACKGROUND Since the early 1990s, the pulmonary autograft is predominantly implanted as a freestanding root for less aortic valve regurgitation is reported. However, there is a certain risk of dilatation of the root over time potentially impairing valve function. We favor since 8 years the original subcoronary or inclusion technique to preserve the root of the patient as a restrain to dilatation. METHODS AND RESULTS Between June 1994 and May 2002 the subcoronary (n=228) and inclusion technique (n=17) were performed in 245 patients (191 male, 54 female), mean age 45.7+/-13.4 (15-70) years. The underlying aortic valve disease was an aortic insufficiency in n=83, stenosis in n=48, a combined aortic valve disease in n=111 and an acute endocarditis in n=19 patients. Previous aortic valve surgery was performed in n=23. Last follow-up investigations (within last year) including echocardiography was performed at a mean follow-up of 29.4+/-24.7 months (553.7 patient years). Hospital mortality was n=2, late mortality n=4 (all noncardiac). Two patients were lost to follow-up (99% complete clinical follow-up). Reoperations were necessary in n=7 valves (autograft: endocarditis n=1, malpositioning n=1, leaflet prolapse n=1; homograft: stenosis n=2, insufficiency n=2). Autograft insufficiency (AI) was AI 0 in n=154, AI I n=66, AI II n=8. The maximum/mean pressure gradient across the autograft was 6.6+/-3.4 (2.1 to 25.9)/3.6+/-1.8 (1.2 to 13.2) mm Hg, respectively. Homograft insufficiency was 0 in n=167, I in n=54, II in n=9, and III in n=1. Maximum and mean transhomograft pressure gradients were 11.7+/-6.8 (2.2 to 42.6)/6.2+/-3.8 (1.2 to 24.5) mm Hg. Most patients were NYHA class I (n=214), class II (n=19), class III (n=2). Significant aortic root dilatation was not observed. CONCLUSIONS Aortic valve replacement with a pulmonary autograft in the subcoronary or inclusion technique provides excellent hemodynamics with no root dilatation at least in a mid term postoperative period. Transhomograft pressure gradients are slightly increased. Longer term results with special emphasis on the pulmonary homograft are necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعویض دریچه آئورت: مقایسه روش متداول و روش جدید

Background: The usage of pericardium of patient himself, for support of anastomosis lines may carry benefits in patients undergoing aortic valve replacement with pulmonary autograft (Ross). The aim of the present study was to compare the short term results of aortic valve replacement with pulmonary autograft with routine and offered methods. Methods: In a non-randomized clinical trial, 64 pati...

متن کامل

Follow-up after the Ross procedure. How significant it is

Background/Introduction Replacement of the aortic valve or aortic root with a pulmonary autograft (Ross procedure) and replacement of the pulmonary valve with a pulmonary allograft or xenograft and is now a widely used technique for the treatment of aortic valve disease in the children and young adult. Excellent short and midterm results have been demonstrated but there is continuing concern ab...

متن کامل

عوامل خطر تنگی هموگرافت پولمونر پس ازعمل جراحی Ross

Background: The Ross procedure has been known as a good method for aortic valve replacement. Pulmonary allograft postoperative stenosis subsequent to the Ross procedure has been noted as an important disadvantage of this technique, although risk factors related to this complication are not clearly recognized. In this study we evaluate the risk factors of pulmonary allograft stenosis after Ross ...

متن کامل

Ross procedure at the crossroads.

The quest for a perfect heart valve substitute has been going on for half a century. In 1960, Lower et al1 described the feasibility of replacing the aortic valve of dogs with the native pulmonary valve. In 1967, Ross performed this procedure in humans.2 Ross transferred the pulmonary valve into the aortic root with the same technique used to implant aortic valve homograft3 (ie, the pulmonary s...

متن کامل

Late aortic dilatation and regurgitation after Ross operation.

The Ross operation, a procedure of replacement of the diseased aortic valve with an autologous pulmonary valve, has many advantages such as no need for anticoagulation therapy and similar valve function and growth potential as native valves. However secondary aortic disease has emerged as a significant complication and indication for reoperation. We report a 48-year-old woman who had Ross opera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 108 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2003