Can the design of glove dispensing boxes influence glove contamination?

نویسندگان

  • O Assadian
  • D J Leaper
  • A Kramer
  • K J Ousey
چکیده

BACKGROUND Few studies have explored the microbial contamination of glove boxes in clinical settings. The objective of this observational study was to investigate whether a new glove packaging system in which single gloves are dispensed vertically, cuff end first, has lower levels of contamination on the gloves and on the surface around the box aperture compared with conventional glove boxes. METHODS Seven participating sites were provided with vertical glove dispensing systems (modified boxes) and conventional boxes. Before opening glove boxes, the surface around the aperture was sampled microbiologically to establish baseline levels of superficial contamination. Once the glove boxes were opened, the first pair of gloves in each box was sampled for viable bacteria. Thereafter, testing sites were visited on a weekly basis over a period of six weeks and the same microbiological assessments were made. RESULTS The surface near the aperture of the modified boxes became significantly less contaminated over time compared with the conventional boxes (P<0.001), with an average of 46.7% less contamination around the aperture. Overall, gloves from modified boxes showed significantly less colony-forming unit contamination than gloves from conventional boxes (P<0.001). Comparing all sites over the entire six-week period, gloves from modified boxes had 88.9% less bacterial contamination. CONCLUSION This simple improvement to glove box design reduces contamination of unused gloves. Such modifications could decrease the risk of microbial cross-transmission in settings that use gloves. However, such advantages do not substitute for strict hand hygiene compliance and appropriate use of non-sterile, single-use gloves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can the Design of Glove Dispensing Boxes Influence Glove Contamination? Original Citation Can the Design of Glove Dispensing Boxes Influence Glove Contamination?

The University Repository is a digital collection of the research output of the University, available on Open Access. Copyright and Moral Rights for the items on this site are retained by the individual author and/or other copyright owners. Users may access full items free of charge; copies of full text items generally can be reproduced, displayed or performed and given to third parties in any ...

متن کامل

Design of a new non-sterile glove-dispensing unit to reduce touch-based contamination.

BACKGROUND Despite best efforts by healthcare providers to sterilise their hands through hand washing prior to touching medical equipment and patients, bacteria are still present and can be spread through physical contact. We aimed to reduce the spread of touch-induced and airborne bacteria and virus spreading by using a touch-free glove-dispensing system that minimally exposes gloves in the bo...

متن کامل

Bacterial contamination of unused, disposable non-sterile gloves on a hospital orthopaedic ward.

BACKGROUND Non-sterile disposable gloves are used on large hospital wards, however their potential role as a vehicle for pathogen transmission has not been explored in this setting. AIMS This study investigates glove use on a hospital orthopaedic ward to examine whether pathogen contamination occurs prior to contact with patients. METHOD Glove samples were aseptically removed from boxes on ...

متن کامل

Intraoperative glove perforation--single versus double gloving in protection against skin contamination.

Surgeons have the highest risk of contact with patients' blood and body fluids, and breaches in gloving material may expose operating room staff to risk of infections. This prospective randomised study was done to assess the effectiveness of the practice of double gloving compared with single gloving in decreasing finger contamination during surgery. In 66 consecutive surgical procedures studie...

متن کامل

Using innovative antimicrobial glove technology to reduce the risk of surgical wound contamination following glove perforation

Introduction / objectives Surgical gloves create a protective barrier, however high perforation rates (6%>60%) are reported in the literature. A recent study has suggested linkage between glove perforation and increased risk of SSI. This investigation evaluated a model of microbial passage through conventional single (A), double-thickness (B) and a tri-layer innovative surgical glove (C) with a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hospital infection

دوره 94 3  شماره 

صفحات  -

تاریخ انتشار 2016