[Evaluation of postoperative myocardial injury by heart-type fatty acid-binding protein in off-pump coronary artery bypass grafting surgery].

نویسندگان

  • P Carmona
  • E Mateo
  • A Montoro
  • L Alós
  • M Coret
  • C L Errando
  • J Llagunes
  • J De Andrés
چکیده

BACKGROUND AND GOAL OF STUDY Postoperative myocardial infarction is a serious and frequent complication of cardiac surgery. Nonetheless, diagnosis in this context it is occasionally challenging. We sought to evaluate the kinetics and diagnostic accuracy of the new biomarker « heart-type fatty acid-binding protein » (h-FABP) in the early detection of myocardial injury in patients undergoing off-pump coronary artery bypass grafting, compared with classical biomarkers. MATERIALS AND METHODS A prospective study was conducted on 17 consecutive patients who underwent off-pump coronary artery bypass grafting during a 2 month period. Blood samples were drawn for measurement of myocardial ischemic injury biomarkers (h-FABP, troponin, creatine kinase [CK] and CK-MB), at baseline (T1), immediate post-coronary artery bypass grafting (T2), on ICU admission (T3), and after 4 (T4), 8 (T5), 24 (T6) and 48 h (T7). Perioperative ischemic complications, defined according to electrocardiographic, echocardiographic and hemodynamic criteria, were recorded. RESULTS Earlier biomarkers peak plasma values occurred at T4 with troponin (2.9 ± 5.2 ng/mL), and at T5 with h-FABP (37.9 ± 55.5 ng/mL). Maximum values of CK and CK-MB occurred later, both in T6 (741 ± 779 and 37 ± 51 U/L, respectively). The optimized cut-off obtained for h-FABP was 19 ng/mL, providing a sensitivity and specificity of 77 and 75%, respectively, for diagnosis of perioperative ischemic injury, with an area under the ROC curve for h-FABP of 0.83 (95% CI 0.6-1.0) vs. 0.63 (95% CI 0.33-0.83) for troponin. This cut-off value for h-FABP is reached on average at T2 (mean value of h-FABP at T2: 18.9 ± 21.5 ng/mL). CONCLUSION This is the first study evaluating the kinetics of h-FABP biomarker in perioperative off-pump coronary artery bypass grafting, and the cut-off value established could help to extend earlier detection of myocardial ischemia in this context.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Avoidance of Dialysis in an End-Stage Renal Disease Patient Status-post Off-pump Coronary Artery Bypass Grafting

Certain benefits are clearly associated with the use of off-pump coronary artery bypass grafting (CABG) as compared with the on-pump CABG. The superiority is more evident in patients with multiple co morbidities including renal failure.We reviewed the medical records of a 67-year-old male with a past medical history that was significant for multiple cardiovascular diseases and new-onset end-sta...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Use of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery

Introduction:  The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...

متن کامل

Off-pump coronary bypass grafting is associated with less myocardial injury than coronary bypass surgery with cardiopulmonary bypass.

BACKGROUND Excessive myocardial necrosis following coronary artery bypass grafting is associated with adverse outcome. The present study was designed to assess the extent of myocardial injury after conventional coronary artery bypass grafting with cardio pulmonary bypass (ONCAB) compared with off-pump coronary artery bypass (OPCAB). METHODS Measurements of serum cardiac troponin T (TnT) were ...

متن کامل

Frequency of Acute Kidney Injury in Patients Treated With Normal Saline after Off-Pump Coronary Artery Bypass Grafting

Introduction: Acute kidney injury (AKI) is a common postoperative complication of cardiac surgery, which is associated with an increased risk of morbidity and mortality. This study investigated the frequency of postoperative AKI in low risk adult patients undergoing off-pump coronary artery bypass grafting (CABG).Materials & Methods: All consecutive adult patients of American Society of Anesthe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de anestesiologia y reanimacion

دوره 62 1  شماره 

صفحات  -

تاریخ انتشار 2015