Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

نویسندگان

  • Jianyan Huang
  • Jyotsna Maram
  • Tudor C Tepelus
  • Cristina Modak
  • Ken Marion
  • SriniVas R Sadda
  • Vikas Chopra
  • Olivia L Lee
چکیده

PURPOSE To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. METHODS Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. RESULTS No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. CONCLUSION Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cigarette Smoking and Pachymetry and Specular Microscopy Parameters of Cornea; A Systematic Review and Meta-analysis

Purpose: To investigate the effect of smoking on corneal parameters, including Endothelial Cell Density, Central Corneal Thickness, Percent of Hexogonality, and Coefficient of Variation. Methods: This study was a systematic review and meta-analysis of published articles until the end of February 2019. To do this, the first search was done for creditable medical databases such as PubMed, and ISI...

متن کامل

Morphological Changes of Human Corneal Endothelial Cells after Rho-Associated Kinase Inhibitor Eye Drop (Ripasudil) Administration: A Prospective Open-Label Clinical Study

PURPOSE To investigate the effect and safety of a selective Rho kinase inhibitor, ripasudil 0.4% eye drops, on corneal endothelial cells of healthy subjects. DESIGN Prospective, interventional case series. METHODS In this study, 6 healthy subjects were administered ripasudil 0.4% in the right eye twice daily for 1 week. Morphological changes and corneal endothelial cell density were examine...

متن کامل

Quantitative and morphological characteristics of the human corneal endothelium in relation to age, gender, and ethnicity in cataract populations of South Asia.

PURPOSE To describe the differences of corneal endothelial cell densities, cell size variability and cell hexagonality in cataract populations of south Asia between sexes and ethnic groups. METHODS 1,235 eyes of 1,235 male and female patients 40-75 years of age with senile cataract were examined with non contact specular microscopy with semi-automated analysis technique. The cell data of the ...

متن کامل

مقایسه‌ی سلول‌های اندوتلیوم قرنیه در افراد مبتلا به قوز قرنیه و سالم

Background: In this study were focused on corneal cells changes in keratoconus disease, as there are differences between results of other studies that were done on keratokonic eyes. And the chief purpose was a comparison between keratoconus and normal population based corneal endothelium (in cell density, pleomorphism and polymegethism of cells). Methods: This study is an observational study a...

متن کامل

Evaluation of corneal endothelium and keratic precipitates by specular microscopy in anterior uveitis.

BACKGROUND The study of corneal endothelium, by specular microscopy, in patients with anterior uveitis has largely been restricted to observations on the endothelial cells. In this prospective study "keratic precipitates" (KP) in different types of uveitis were examined in different stages of the disease process and the endothelial changes occurring in the vicinity of the KP were evaluated in c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of optometry

دوره   شماره 

صفحات  -

تاریخ انتشار 2017