N-bromosuccinimide-fluorescein based sensitive flow-injection chemiluminescence determination of phenformin.

نویسندگان

  • Zhouping Wang
  • Zhujun Zhang
  • Zhifeng Fu
  • Luqiu Fang
  • Xiao Zhang
چکیده

A novel and highly sensitive method for the determination of phenformin over the range of 6 x 10(-9) - 1 x 10(-5) g ml(-1) in pharmaceutical formulations with flow-injection chemiluminescence (CL) detection is proposed. The method is based on the CL produced during the oxidation of N-bromosuccinimide (NBS) in an alkaline medium in the presence of fluorescein as an effective energy transfer agent. The use of cetyltrimethylammonium bromide (CTAB) as a sensitizer enhances the signal magnitude by about 100 times. The detection limit is 2 x 10(-9) g ml(-1) (3sigma) with a relative standard deviation of 2.3% (n = 11) at 1 x 10(-7) g ml(-1) phenformin. Ninety samples can be determined per hour. The method was evaluated by carrying out a recovery study and by the analysis of commercial formulations. The obtained results compared well with those by an official method, and demonstrated good accuracy and precision. The possible CL mechanism of the proposed system was also briefly analyzed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Post-chemiluminescence phenomenon of NBS-luminol reactions and their applications to flow injection analysis of piroxicam.

A new post-chemiluminescence (PCL) reaction was observed when piroxicam was injected into the reaction mixture after the CL reaction of N-bromosuccinimide (NBS) and luminol. A possible reaction mechanism was proposed based on the studies of the CL kinetic characteristics, the CL spectra, fluorescence spectra and other experiments. A new flow injection CL method for the determination of piroxica...

متن کامل

Development of a sensitive flow injection-chemiluminescence detection method for the indirect determination of propranolol

A highly sensitive flow injection-chemiluminescence detection (FI-CL) method based on pyrogallol (Pg) chemiluminescent reagent (CLreagent) oxidized by periodate for the determination of propranolol is presented. The presented method is an indirect CL detection method based on the CL emission generated during the oxidation of Pg with the excess of periodate that remains after oxidation of propra...

متن کامل

Chemiluminescence Determination of Some Fluoroquinolones Using NBS-Luminol System

A new, simple, rapid and sensitive batch chemiluminescence (CL) method for determination of six fluoroquinolones (ciprofloxacin, gatifloxacin, levofloxacin, lomefloxacin HCl, ofloxacin and sparfloxacin) is proposd. The method is based on the CL generated during the oxidation of luminol by N-bromosuccinimide (NBS) in alkaline medium. The determination of the studied drugs is based on their inhib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 2004