Evaluation of surface contamination with cyclophosphamide following simulated hazardous drug preparation activities using two closed-system products

نویسندگان

  • Matthew D Zock
  • Scott Soefje
  • Keith Rickabaugh
چکیده

PURPOSE A preliminary investigation was conducted to evaluate and compare the effectiveness of two closed-system products in preventing contamination of typical pharmacy workplace surfaces with cyclophosphamide during simulated hazardous drug preparation activities in a controlled laboratory setting. METHODS Two separate trials simulating hazardous drug compounding using cyclophosphamide were performed with two different closed-system products. Prior to each trial, work area surfaces of the biological safety cabinet (BSC) workbench, the BSC airfoil and front grill, and the floor below the BSC were cleaned, and wipe samples were collected and analyzed to determine, if present, levels of cyclophosphamide. Following each trial, wipe samples were collected from the work area surfaces to determine the hazardous drug containment effectiveness of each closed-system product. RESULTS Cyclophosphamide was not detected on work area surfaces prior to each trial. Low levels were detected on the BSC workbench surface following both trials. DISCUSSION Based on the limited number of samples obtained during this preliminary study and the determination of the presence of the chemical of interest on the drug vials, no statistical evaluation was performed to compare the relative effectiveness of the two systems tested. Work practices and procedures regarding product operation may affect hazardous drug containment and worker safety. Further study and statistical analyses are needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and evaluation of a novel product to remove surface contamination of hazardous drugs.

Background Even while following best practices, surface exposures of hazardous drugs (HDs) are high and numerous. Thus, it is important to develop new products to reduce the surface contamination of HDs. Hazardous Drug Clean (HDClean™) was developed to decontaminate and remove HDs from various types of surfaces and overcome the problems associated with other cleaning products. Methods HDClean w...

متن کامل

Impact of closed-system drug transfer device on exposure of environment and healthcare provider to cyclophosphamide in Japanese hospital

In spite of current recommended safe handling procedures, the potential for the exposure of healthcare providers to hazardous drugs exists in the workplace. A reliance on biological safety cabinets to provide total protection against the exposure to hazardous drugs is insufficient. Preventing workplace contamination is the best strategy to minimize cytotoxic drug exposure in healthcare provider...

متن کامل

بررسی آلودگی سطوح با داروهای سیکلوفسفامید و ایفسفامید در مراکز کموتراپی

  Background and purpose: Cyclophosphamide and ifosfamide are two most widely used and hazardous drugs in chemotherapy centers. This study aimed at determining surface contamination with cyclophosphamide and iphosphamide in chemotherapy centers. Materials and methods: This descriptive cross-sectional study was carried out in three chemotherapy centers affiliated with Hamedan University o...

متن کامل

Determining Sources of Workplace Contamination with Antineoplastic Drugs and Comparing Conventional IV Drug Preparation with a Closed System

Many procedures involved in the preparation and administration of hazardous drugs put health care workers at risk of exposure to these agents through leakage or accidental spills. The first objective of this study was to determine if the conventional needle/syringe technique has the potential to allow drugs to escape into the environment. The second objective was to evaluate if a closed system,...

متن کامل

Comparative Study of Syringe Contamination by Hazardous Drugs

Aim e purpose of this study was to compare surface contamination resulting from standard syringe plungers and cylinders compared to using the EQUASHIELD® Syringe Unit. Method e contamination level of standard syringes was compared to that of EQUASHIELD® Syringe Units, after repeated pharmaceutical manipulations using an antineoplastic (Cyclophosphamide) drug. Results Signi cant levels of up to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2011