The Systematic Bias of Ingestible Core Temperature Sensors Requires a Correction by Linear Regression
نویسندگان
چکیده
An accurate measure of core body temperature is critical for monitoring individuals, groups and teams undertaking physical activity in situations of high heat stress or prolonged cold exposure. This study examined the range in systematic bias of ingestible temperature sensors compared to a certified and traceable reference thermometer. A total of 119 ingestible temperature sensors were immersed in a circulated water bath at five water temperatures (TEMP A: 35.12 ± 0.60°C, TEMP B: 37.33 ± 0.56°C, TEMP C: 39.48 ± 0.73°C, TEMP D: 41.58 ± 0.97°C, and TEMP E: 43.47 ± 1.07°C) along with a certified traceable reference thermometer. Thirteen sensors (10.9%) demonstrated a systematic bias > ±0.1°C, of which 4 (3.3%) were > ± 0.5°C. Limits of agreement (95%) indicated that systematic bias would likely fall in the range of -0.14 to 0.26°C, highlighting that it is possible for temperatures measured between sensors to differ by more than 0.4°C. The proportion of sensors with systematic bias > ±0.1°C (10.9%) confirms that ingestible temperature sensors require correction to ensure their accuracy. An individualized linear correction achieved a mean systematic bias of 0.00°C, and limits of agreement (95%) to 0.00-0.00°C, with 100% of sensors achieving ±0.1°C accuracy. Alternatively, a generalized linear function (Corrected Temperature (°C) = 1.00375 × Sensor Temperature (°C) - 0.205549), produced as the average slope and intercept of a sub-set of 51 sensors and excluding sensors with accuracy outside ±0.5°C, reduced the systematic bias to < ±0.1°C in 98.4% of the remaining sensors (n = 64). In conclusion, these data show that using an uncalibrated ingestible temperature sensor may provide inaccurate data that still appears to be statistically, physiologically, and clinically meaningful. Correction of sensor temperature to a reference thermometer by linear function eliminates this systematic bias (individualized functions) or ensures systematic bias is within ±0.1°C in 98% of the sensors (generalized function).
منابع مشابه
Issues in Continuous 24-h Core Body Temperature Monitoring in Humans Using an Ingestible Capsule Telemetric Sensor
BACKGROUND There is increasing interest in the use of pill-sized ingestible capsule telemetric sensors for assessing core body temperature (Tc) as a potential indicator of variability in metabolic efficiency and thrifty metabolic traits. The aim of this study was to investigate the feasibility and accuracy of measuring Tc using the CorTemp® system. METHODS Tc was measured over an average of 2...
متن کاملCalibration of an ingestible temperature sensor.
An ingestible telemetric sensor for measuring core body temperature is increasingly being utilized in occupational and athletic studies of heat strain. There is a need for a uniform method of calibrating these sensors in the scientific community in order to effectively compare the results of different researchers. The purpose of the present investigation was to determine and present such a cali...
متن کاملEvaluating the Application of Reinforcement Correction Factor for Concrete Core Testing
This study investigates the reinforcement correction factor of concrete core in more detail to prepare appropriate outlines for interpretation of results. This investigation aims to minimize uncertainties involved to carry out the more realistic condition assessment of suspect buildings before taking up retrofitting/strengthening measures. For this purpose, an extensive experimental program inc...
متن کاملمعرفی روش تطبیقی اصلاح شده برای اندازهگیری دقیق ولتاژ در مبدل ولتاژ نوری
There are fewer problems encountered with optical voltage transducers in comparison with their inductive and capacitive counterparts. Although capacitive and inductive transformers are used vastly for the purpose of measurement and protection in the networks, they cause problems such as core saturation and improper transient responses which decrease the accuracy of measurement and eficiency of ...
متن کاملNoise Equivalent Power Optimization of Graphene- Superconductor Optical Sensors in the Current Bias Mode
In this paper, the noise equivalent power (NEP) of an optical sensor based ongraphene-superconductor junctions in the constant current mode of operation has beencalculated. Furthermore, the necessary investigations to optimize the device noise withrespect to various parameters such as the operating temperature, magnetic field, deviceresistance, voltage and current bias have been presented. By s...
متن کامل