Detection of ‘best’ positive end-expiratory pressure derived from electrical impedance tomography parameters during a decremental positive end-expiratory pressure trial

نویسندگان

  • Paul Blankman
  • Djo Hasan
  • Groot Jebbink Erik
  • Diederik Gommers
چکیده

INTRODUCTION This study compares different parameters derived from electrical impedance tomography (EIT) data to define 'best' positive end-expiratory pressure (PEEP) during a decremental PEEP trial in mechanically-ventilated patients. 'Best' PEEP is regarded as minimal lung collapse and overdistention in order to prevent ventilator-induced lung injury. METHODS A decremental PEEP trial (from 15 to 0 cm H2O PEEP in 4 steps) was performed in 12 post-cardiac surgery patients on the ICU. At each PEEP step, EIT measurements were performed and from this data the following were calculated: tidal impedance variation (TIV), regional compliance, ventilation surface area (VSA), center of ventilation (COV), regional ventilation delay (RVD index), global inhomogeneity (GI index), and intratidal gas distribution. From the latter parameter we developed the ITV index as a new homogeneity parameter. The EIT parameters were compared with dynamic compliance and the PaO2/FiO2 ratio. RESULTS Dynamic compliance and the PaO2/FiO2 ratio had the highest value at 10 and 15 cm H2O PEEP, respectively. TIV, regional compliance and VSA had a maximum value at 5 cm H2O PEEP for the non-dependent lung region and a maximal value at 15 cm H2O PEEP for the dependent lung region. GI index showed the lowest value at 10 cm H2O PEEP, whereas for COV and the RVD index this was at 15 cm H2O PEEP. The intratidal gas distribution showed an equal contribution of both lung regions at a specific PEEP level in each patient. CONCLUSION In post-cardiac surgery patients, the ITV index was comparable with dynamic compliance to indicate 'best' PEEP. The ITV index can visualize the PEEP level at which ventilation of the non-dependent region is diminished, indicating overdistention. Additional studies should test whether application of this specific PEEP level leads to better outcome and also confirm these results in patients with acute respiratory distress syndrome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial

INTRODUCTION Computed tomography of the lung has shown that ventilation shifts from dependent to nondependent lung regions. In this study, we investigated whether, at the bedside, electrical impedance tomography (EIT) at the cranial and caudal thoracic levels can be used to visualize changes in ventilation distribution during a decremental positive end-expiratory pressure (PEEP) trial and the r...

متن کامل

Electrical impedance tomography to evaluate air distribution prior to extubation in very-low-birth-weight infants: a feasibility study

OBJECTIVES Nasal continuous positive airway pressure is used as a standard of care after extubation in very-low-birth-weight infants. A pressure of 5 cmH2O is usually applied regardless of individual differences in lung compliance. Current methods for evaluation of lung compliance and air distribution in the lungs are thus imprecise for preterm infants. This study used electrical impedance tomo...

متن کامل

Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients

INTRODUCTION As it becomes clear that mechanical ventilation can exaggerate lung injury, individual titration of ventilator settings is of special interest. Electrical impedance tomography (EIT) has been proposed as a bedside, regional monitoring tool to guide these settings. In the present study we evaluate the use of ventilation distribution change maps (DeltafEIT maps) in intensive care unit...

متن کامل

Effect of body position on ventilation distribution during PEEP titration in a porcine model of acute lung injury using advanced respiratory monitoring and electrical impedance tomography

BACKGROUND Lung failure after acute lung injury remains a challenge in different clinical settings. Various interventions for restoration of gas exchange have been investigated. Recruitment of collapsed alveoli by positive end expiratory pressure (PEEP) titration and optimization of ventilation-perfusion ratio by prone positioning have been extensively described in animal and clinical trials. T...

متن کامل

Positive End-expiratory Pressure Titration after Alveolar Recruitment Directed by Electrical Impedance Tomography

BACKGROUND Electrical impedance tomography (EIT) is a real-time bedside monitoring tool, which can reflect dynamic regional lung ventilation. The aim of the present study was to monitor regional gas distribution in patients with acute respiratory distress syndrome (ARDS) during positive-end-expiratory pressure (PEEP) titration using EIT. METHODS Eighteen ARDS patients under mechanical ventila...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2014