Correlation between the Charge of Proteins in Solution and in the Gas Phase Investigated by Protein Charge Ladders, Capillary Electrophoresis, and Electrospray Ionization Mass Spectrometry
نویسندگان
چکیده
Charge ladders of bovine carbonic anhydrase II, hen egg-white lysozyme, and bovine pancreatic trypsin inhibitor, prepared by partial acetylation of primary amino groups on the surface of the protein, have been analyzed by capillary electrophoresis (CE) and on-line electrospray ionization mass spectrometry (ESIMS) using solution conditions that maintain the native structure of the protein. CE was used to separate the proteins that constitute the charge ladder into individual “rungs”sprotein derivatives that have the same number of acetylated amino groups and approximately the same net charge in solution. ESI was used to produce ions in the gas phase of the proteins that constitute each rung of the charge ladder; the mass spectra of these ions were obtained and analyzed. The distributions in charge states observed in the gas phase for the groups of proteins comprising each rung of the charge ladders were narrow, consistent with the retention of a compact structure of the proteins in the gas phase, and substantially independent of the number of acetylated amino groups. The ions observed in the gas phase had surface charge densities in a relatively narrow range of ∼0.9-1.5 units of charge per 103 Å2 of surface area (as estimated from crystallographic structures). These results demonstrate that the distribution of charge states for proteins produced in the gas phase by ESI do not necessarily reflect the net charge of the protein in solution or the number of amino groups on the protein.
منابع مشابه
A study of the thermal denaturation of ribonuclease S by electrospray ionization mass spectrometry.
The thermal stability of ribonuclease S (RNase S), an enzymatically active noncovalent complex composed of a 2166-u peptide (S-peptide) and a 11,534-u protein (S-protein), was investigated by electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis ESI-MS (CE-ESI-MS). The intensities of peaks corresponding to the RNase S complex were inversely related to both the applied...
متن کاملEstimates of protein surface areas in solution by electrospray ionization mass spectrometry.
The extent of multiple charging of protein ions in electrospray ionization (ESI) mass spectra depends on the solvent-exposed surface area, but it may also be influenced by a variety of other extrinsic and intrinsic factors. Gas-phase ion chemistry (charge-transfer and charge-partitioning reactions) appears to be the major extrinsic factor influencing the extent of protonation as detected by ESI...
متن کاملSolvent-induced structural transitions of lysozyme in an electrospray ionization source.
The structural characterization of proteins using electrospray ionization mass spectrometry (ESI-MS) has become an important method for understanding protein structural dynamics. The correlation between the structures of proteins in solution and gas phase needs to be understood for the application of ESI-MS to protein structural studies. Hen egg white lysozyme (Lyz) is a small protein with a st...
متن کاملEffects of anions on the positive ion electrospray ionization mass spectra of peptides and proteins.
Positive ion electrospray ionization mass spectra of polypeptides are usually obtained from solutions that are acidified and therefore contain relatively high concentrations of anions. The present study describes an investigation of the effects of these ubiquitous anions on the positive ion electrospray ionization mass spectra of peptides and proteins. Certain anionic species in the spray solut...
متن کاملSheathless capillary electrophoresis/electrospray ionization mass spectrometry using a pulled bare fused-silica capillary as the electrospray emitter.
It has always been assumed that electrical contact at the capillary outlet is a necessary requirement when coupling capillary electrophoresis (CE) with electrospray ionization mass spectrometry (ESI-MS). In this study, we used a pulled bare-capillary tip as the ESI emitter, but neither was it coated with any electrically conductive materials nor was a high external voltage applied on its outlet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1998