Chondroitin sulphate (WF6 epitope) levels in peri-miniscrew implant crevicular fluid during orthodontic loading.

نویسندگان

  • Imjai Intachai
  • Suttichai Krisanaprakornkit
  • Prachya Kongtawelert
  • Siriwan Ong-chai
  • Boonsiva Buranastidporn
  • Eduardo Yugo Suzuki
  • Dhirawat Jotikasthira
چکیده

The aim of this study was to monitor changes in chondroitin sulphate (CS; WF6 epitope) levels in peri-miniscrew implant crevicular fluid (PMICF) during orthodontic loading. Ten patients (seven males and three females; aged 22.0 +/- 3.4 years), who required orthodontic treatment with extraction of all four premolar teeth, participated in the study. Twenty miniscrew implants (used as orthodontic anchorage) were placed, two in each patient, buccally and bilaterally in the alveolar bone between the roots of the maxillary posterior teeth. Sentalloy closed-coil springs (50 g) were used to load the miniscrew implants and to move the maxillary canines distally. During the unloaded period, PMICF samples were collected on days 1, 3, 5, and 7 after miniscrew implant placement and on days 14, 21, 28, and 35 during the loaded period. Clinical mobility assessments of the miniscrew implants were recorded at each visit. The competitive enzyme-linked immunosorbent assay with monoclonal antibody WF6 was used to detect CS (WF6 epitope) levels in the PMICF samples. The differences between the CS (WF6 epitope) levels during the unloaded and loaded periods were determined by a Mann-Whitney U-test. During the loaded period, two miniscrew implants were considered to have failed. The CS (WF6 epitope) levels during the unloaded period ranged from 0.00 to 758.03 ng/ml and those during the loaded period from 0.00 to 1025.11 ng/ml. Medians of CS (WF6 epitope) levels, around 'immobile' miniscrew implants, between the unloaded and loaded periods were not significantly different (P = 0.07). CS (WF6 epitope) levels in PMICF can be detected and may be used as biomarkers for assessing alveolar bone remodelling around miniscrew implants during orthodontic loading.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A review of biomarkers in peri-miniscrew implant crevicular fluid (PMICF)

BACKGROUND The temporary anchorage devices (TADs) which include miniscrew implants (MSIs) have evolved as useful armamentarium in the management of severe malocclusions and assist in complex tooth movements. Although a multitude of factors is responsible for the primary and secondary stability of miniscrew implants, contemporary research highlights the importance of biological interface of MSI ...

متن کامل

A study of interleukin 1β levels in peri-miniscrew crevicular fluid (PMCF)

BACKGROUND This study provides a vital insight in assessing the clinical and biochemical changes in interleukin (IL)-1β levels in peri-miniscrew crevicular fluid (PMCF) during the course of orthodontic tooth movement. METHODS The study comprised the analysis of IL-1β in peri-miniscrew crevicular fluid obtained from crevices around the miniscrews inserted in 11 patients (eight females and thre...

متن کامل

Identification of interleukin 2, 6, and 8 levels around miniscrews during orthodontic tooth movement.

The aim of this study was to identify the levels of interleukin (IL)-2, IL-6, and IL-8 around miniscrews used for anchorage during canine distalization. Sixteen patients (eight males and eight females; mean age, 16.6 ± 2.4 years) who were treated with bilateral upper first premolar extractions were included in the study. Thirty-two maxillary miniscrew implants were placed bilaterally in the alv...

متن کامل

Receptor Activator of Nuclear Factor Kappa B Ligand (RANKL) Levels in Peri-Implant Crevicular Fluid

Background: Receptor activator of nuclear factor kappa B ligand (RANKL) is one of the key cytokines in the induction of osteoclastogenesis both in vitro and in vivo.Several reports indicated the presence of sRANKL in gingival crevicular fluid of patients with periodontal diseases. Objective: To determine the presence of RANKL in peri-implant crevicular fluid samples of implants with peri-implan...

متن کامل

Risks and complications of orthodontic miniscrews.

The risks associated with miniscrew placement should be clearly understood by both the clinician and the patient. Complications can arise during miniscrew placement and after orthodontic loading that affect stability and patient safety. A thorough understanding of proper placement technique, bone density and landscape, peri-implant soft-tissue, regional anatomic structures, and patient home car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 2010