Guide wire knot during double J catheter insertion: case report.
نویسندگان
چکیده
OBJECTIVE To report one case of intrapyelic loop of a guide wire during double J catheter insertion. METHODS We report the case of a 24 year-old female, with the diagnosis obstructive uropathy secondary to pelvic tumor who required double J catheter insertion for urinary diversion. A loop of the guide wire was formed during the procedure which was finally solved without aggressive measures. RESULTS We report the case of a rare complication appeared during urinary catheter insertion procedure, as well as a review of the current literature. CONCLUSION The use of guide wires and endourological catheters is not free of complications that may require aggressive measures to be solved.
منابع مشابه
حل مشکل جاگذاری کاتتر ورید مرکزی با استفاده از کاتتر وریدی: مقاله تکنیکال
Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will ...
متن کاملGuide Wire Induced Cardiac Tamponade: The Soft J Tip Is Not So Benign
Central venous catheter (CVC) insertion rarely causes cardiac tamponade due to perforation. Although it is a rare complication, it can be lethal if not identified early. We report a case of cardiac tamponade caused by internal jugular (IJ) central venous catheter (CVC) insertion using a soft J-tipped guide wire which is considered safe and rarely implicated with cardiac tamponade. A bedside tra...
متن کاملIatrogenic Transient Complete Heart Block in a Preexisting LBBB
Catheter induced cardiac arrhythmia is a well-known complication encountered during pulmonary artery or cardiac catheterization. Injury to the cardiac conducting system often involves the right bundle branch which in a patient with preexisting left bundle branch block can lead to fatal arrhythmia including asystole. Such a complication during central venous cannulation is rare as it usually doe...
متن کاملSuccessful removal of kinked J-guide wire under fluoroscopic guidance during central venous catheterization -A case report-
Guidewire-associated complications that occur during the process of central venous catheterization include its kinking, looping, knotting and breakage. The removal of a looped or knotted guidewire is problematic because it can cause vessel damage, major hemorrhage, or embolization of a fractured guidewire. We report a case of guidewire kinking and its successful removal under fluoroscopic guida...
متن کاملEUS-guided pseudocyst drainage as a one-step procedure using a novel multiple wire insertion technique.
technique of endoscopic ultrasound (EUS)-guided pseudocyst drainage as a one-step procedure using a novel multiple wire insertion technique facilitated by the double-lumen biliary cytology brush catheter (Cook Medical, Winston-Salem, North Carolina, USA). Six symptomatic patients underwent EUS-guided pseudocyst drainage using the novel multiple wire insertion technique (●" Video 1). After ensur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archivos espanoles de urologia
دوره 64 2 شماره
صفحات -
تاریخ انتشار 2011