Visual outcomes and subjective experience after bilateral implantation of a new diffractive trifocal intraocular lens.

نویسندگان

  • Amy L Sheppard
  • Sunil Shah
  • Uday Bhatt
  • Gurpreet Bhogal
  • James S Wolffsohn
چکیده

PURPOSE To assess clinical outcomes and subjective experience after bilateral implantation of a diffractive trifocal intraocular lens (IOL). SETTING Midland Eye Institute, Solihull, United Kingdom. DESIGN Cohort study. METHODS Patients had bilateral implantation of Finevision trifocal IOLs. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and manifest refraction were measured 2 months postoperatively. Defocus curves were assessed under photopic and mesopic conditions over a range of +1.50 to -4.00 diopters (D) in 0.50 D steps. Contrast sensitivity function was assessed under photopic conditions. Halometry was used to measure the angular size of monocular and binocular photopic scotomas arising from a glare source. Patient satisfaction with uncorrected near vision was assessed using the Near Activity Visual Questionnaire (NAVQ). RESULTS The mean monocular CDVA was 0.08 logMAR ± 0.08 (SD) and the mean binocular CDVA, 0.06 ± 0.08 logMAR. Defocus curve testing showed an extended range of clear vision from +1.00 to -2.50 D defocus, with a significant difference in acuity between photopic conditions and mesopic conditions at -1.50 D defocus only. Photopic contrast sensitivity was significantly better binocularly than monocularly at all spatial frequencies. Halometry showed a glare scotoma of a mean size similar to that in previous studies of multifocal and accommodating IOLs; there were no subjective complaints of dysphotopsia. The mean NAVQ Rasch score for satisfaction with near vision was 15.9 ± 10.7 logits. CONCLUSIONS The trifocal IOL implanted binocularly produced good distance visual acuity and near and intermediate visual function. Patients were very satisfied with their uncorrected near vision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens

Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (A...

متن کامل

Clinical outcomes of a new diffractive trifocal intraocular lens with Enhanced Depth of Focus (EDOF)

BACKGROUND To evaluate the clinical outcomes after the implantation of a new trifocal diffractive intraocular lens (IOL) combined with Enhanced depth of focus (EDOF) technology. METHODS The study enrolled 80 eyes of 40 patients who underwent cataract surgery with bilateral implantation of a diffractive trifocal IOL (Reviol Tri-ED) designed with a combination of enhanced depth of focus. Mean a...

متن کامل

Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

PURPOSE To compare the visual acuity (VA) and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL) and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye. PATIENTS AND METHODS Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnost...

متن کامل

Visual performance after the implantation of a new trifocal intraocular lens

PURPOSE To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens. METHODS A NEW TRIFOCAL DIFFRACTIVE INTRAOCULAR LENS WAS DESIGNED COMBINING TWO SUPERIMPOSED DIFFRACTIVE PROFILES: one with +1.75 diopters (D) addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 2013