Correlation of tear clearance rate and fluorophotometric assessment of tear turnover.
نویسندگان
چکیده
BACKGROUND The study sought to determine dynamic changes and theoretical bases of a clinical diagnostic test, the tear clearance rate. METHODS Thirty four healthy subjects ranging in age from 22 to 84 years underwent examination of tear clearance rate, the Schirmer test with anaesthesia, as well as fluorophotometric measurement of tear turnover, tear volume, and tear flow. By applying 0.5% fluorescein into the conjunctival sac and subsequently measuring colour fades on a Schirmer strip, the tear clearance rate for assessing tear drainage was divided into nine grades. The results of the tear clearance rate were compared with those of the basal tear turnover and tear flow obtained from fluorophotometry. RESULTS Significant relations were found between the tear clearance rate and the basal tear turnover or tear flow (r = 0.91 and 0.79, respectively, p = 0.0001). Considering the grades of progression from low to high, each grade of tear clearance rate showed a 12.5% increase in basal tear turnover (3.59%/min) and tear flow (0.38 microliter/min). There was no significant correlation between age and the basal tear turnover, tear volume, tear flow, or the tear clearance rate. CONCLUSION The tear clearance rate is proposed as a simple and useful way to estimate basal tear turnover and tear flow, and measure tear drainage indirectly.
منابع مشابه
Assessment of tear film dynamics: quantification approach.
The dynamics of the tear film are reviewed with specific reference to the biophysical aspects: distribution, turnover and elimination through evaporation, drainage, and absorption. The review concentrates on quantitative assessments and is confined to aspects of the dynamics that can be fully and directly measured. The techniques of fluorophotometry, fluorescein clearance, lacrimal scintigraphy...
متن کاملFluorophotometric measurement of the precorneal residence time of topically applied hyaluronic acid.
PURPOSE This study was performed to separately assess the aqueous flow applied with hyaluronic acid, and the behaviour of hyaluronic acid itself on the ocular surface. METHODS Two different fluorescent dyes, fluorescein sodium dissolved in 0.1% hyaluronic acid (HA) solution and 0.1% fluorescein conjugated with hyaluronic acid (F-HA) dissolved in saline, were used. A volume of 20 mul of tested...
متن کاملEffect of nonisotonic solutions on tear film osmolality.
We found that the original osmolality of the tear film is regained rapidly subsequent to the installation of hypotonic artificial tears or other nonisotonic solutions. The minor irritation due to nonisotonicity and the increased tear volume both contribute to the increased turnover rate which in turn results in the short half-life (measured in seconds) of these solutions in the eye. Despite the...
متن کاملArthroscopic repair of complete tear of rotator cuff
Abstract Background: Rotator cuff tear is one of the most common causes of shoulder complaints in the elderly. Based on the severity and patient's condition, a variety of methods applies to manage the tear and surgery is an important method, which could be done by open or arthroscopic technique. The current study aimed to investigate and report short-term results of arthroscopic repair of...
متن کاملبررسی اثرات آیوهگزول بر ترکیبات بیوشیمیایی اشک در نمونه حیوانی بزرگ
Background and Purpose: Dacryocystography or visualization of nasolacrimal duct has been widely used in the assessment of the nasal lacrimal system. The water-soluble agent iohexol is currently widely used in nervous and vascular lesion in diagnostic radiology and also employed in dacryocystography. This study was performed to determine the effects of iohexol on tear parameters in normal donk...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 79 11 شماره
صفحات -
تاریخ انتشار 1995