Reliability of a single-session isokinetic and isometric strength measurement protocol in older men.
نویسندگان
چکیده
BACKGROUND The purposes of the current study were (a) to determine the test-retest reliability of a single-session isokinetic and isometric strength testing protocol in older healthy men, and (b) to compare the outcomes of the reliability measures derived from averaged torque scores with those derived from a single peak torque score. METHODS In 19 men (mean age, 72 +/- 5 years), both lower limbs were assessed independently on 2 separate test days using the Biodex System 3 dynamometer. After completing a 5-minute warm-up, each man performed three submaximal knee extensions followed by five maximal contractions at 90 degrees /s (CON), 0 degrees /s (ISO), and -90 degrees /s (ECC). Average (best 3 of 5) and peak CON, ISO, and ECC torque, and CON work and CON power were determined. Peak CON work and CON power were recorded from the highest peak torque concentric contraction (HPTCC). RESULTS Intraclass correlation coefficients ranging from 0.84 to 0.94 were found to have good reliability. The typical error as a coefficient of variation ranged from 8% to 10% for averaged measures and from 8% to 17% for peak torque and HPTCC. The ratio limits of agreement for average and peak CON, ISO, and ECC torque ranged from 23% to 33% and from 40% to 54% for average CON and HPTCC work and power. CONCLUSIONS The test-retest reliability of a single-session isokinetic and isometric strength testing protocol in this group of older healthy men displayed good relative reliability (intraclass correlation coefficient > 0.84); however, because the typical error as a coefficient of variation and ratio limits of agreement (absolute reliability) were large, single-session testing is not recommended.
منابع مشابه
Between-Session Reliability of Common Strength- and Power-Related Measures in Adolescent Athletes
The purpose of this study was to investigate the between-session reliability of common strengthand power-related measures in adolescent athletes. Seventeen adolescent athletes (males: n = 8: age 17.1 ± 2.2 years; height 175.6 ± 3.5 cm; mass 80.2 ± 3.6 kg; females: n = 9; age 16.9 ± 2.6 years; height 178.5 ± 4.3 cm; mass 71.5 ± 4.5 kg) participated in this study. Isokinetic dynamometry, isometri...
متن کاملIsometric and isokinetic muscle strength in the upper extremity can be reliably measured in persons with chronic stroke.
OBJECTIVE To evaluate the test-retest reliability of isometric and isokinetic muscle strength measurements in the upper extremity after stroke. DESIGN A test-retest design. SUBJECTS Forty-five persons with mild to moderate paresis in the upper extremity > 6 months post-stroke. METHODS Isometric arm strength (shoulder abduction, elbow flexion), isokinetic arm strength (elbow extension/flex...
متن کاملCalf-raise senior: a new test for assessment of plantar flexor muscle strength in older adults: protocol, validity, and reliability
PURPOSE This study aimed to develop a new field test protocol with a standardized measurement of strength and power in plantar flexor muscles targeted to functionally independent older adults, the calf-raise senior (CRS) test, and also evaluate its reliability and validity. PATIENTS AND METHODS Forty-one subjects aged 65 years and older of both sexes participated in five different cross-secti...
متن کاملReliability and Minimum Detectable Change for Common Clinical Physical Function Tests in Sarcopenic Men and Women.
OBJECTIVES To determine the test-retest reliability and minimum detectable change scores for seven common clinical measurements of muscle strength and physical function in a multiethnic sample of sarcopenic, malnourished men and women. DESIGN Each participant visited the laboratory seven times over 25 to 26 weeks. Reliability was assessed for each measurement from Familiarization 1 to Familia...
متن کاملReliability of knee extensor and flexor muscle strength measurements in persons with late effects of polio.
OBJECTIVE To assess the reliability of knee extensor and flexor muscle strength measurements in persons with late effects of polio. DESIGN A test-retest reliability study. SUBJECTS Thirty men and women (mean age 63 (standard deviation 6.4) years) with verified late effects of polio. METHODS Knee extensor and flexor muscle strength in both lower limbs were measured twice 7 days apart using...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journals of gerontology. Series A, Biological sciences and medical sciences
دوره 60 1 شماره
صفحات -
تاریخ انتشار 2005