Comparing Model-free Motion Prediction and On-line Model Checking for Respiratory Motion Management

نویسندگان

  • Sven-Thomas Antoni
  • Jonas Rinast
  • Sibylle Schupp
  • Alexander Schlaefer
چکیده

Compensating for respiratory motion is a key challenge for stereotactic body radiation therapy. To overcome latencies in the systems, prediction of future motion is necessary. This is related to the assumption of a stable correlation between external and internal motion. We present a new application for on-line model checking to introduce fail-safety to respiratory motion prediction and show its relevance by comparing to the widely used nLMS predictor. We demonstrate that the regularity of the external motion can be modeled and tested using OMC and deviations from regular respiratory motion can be detected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study

Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...

متن کامل

Reducing False Discovery Rates for On-line Model Checking Based Detection of Respiratory Motion Artifacts

Compensating respiratory motion in radiosurgery is an important problem and can lead to a more focused dose delivered to the patient. We previously showed the negative effect of respiratory artifacts on the error of the correlation model, connecting external and internal motion, for meaningful episodes from treatments with the Accuray CyberKnifer. We applied on-line model checking, an iterative...

متن کامل

A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates

Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback

Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015