A Microwave Radiometer for Internal Body Temperature Measurement
نویسندگان
چکیده
منابع مشابه
Initial Plan for a Precision Temperature Sensor
Precision microwave radiometry requires accurate internal calibration sources. A microwave terminator is one such internal source, and, under the assumption of a high quality match, produces a noise power directly proportional to the physical temperature of the terminator. Precise measurement of this temperature is required in order to provide a quality calibration standard. It is desirable for...
متن کاملA Multipoint Correction Method for Environmental Temperature Changes in Airborne Double-Antenna Microwave Radiometers
This manuscript describes a new type Ka-band airborne double-antenna microwave radiometer (ADAMR) designed for detecting atmospheric supercooled water content (SCWC). The source of the measurement error is investigated by analyzing the model of the system gain factor and the principle of the auto-gain compensative technique utilized in the radiometer. Then, a multipoint temperature correction m...
متن کاملVerification of L-band Fully Polarimetric Noise Injection Radiometer Measurement Capability
Abstract A functional test to verify the proper and accurate measurement capability of an L-band fully polarimetric noise injection radiometer is presented. The test is designed specifically for the MDPP-2 (MIRAS Demonstrator Pilot Project 2) NIR (Noise Injection Radiometer), which has two functions: (1) to calibrate the MIRAS (Microwave Imaging Radiometer using Aperture Synthesis) instrument b...
متن کاملDevelopment and Characterization of Fully Polarimetric Noise Injection Radiometer for MIRAS
An L-band noise injection radiometer (NIR) has been designed and implemented by Helsinki University of Technology Laboratory of Space Technology for the SMOS (Soil Moisture and Ocean Salinity) mission of ESA [1]. The work is performed as a part of ESA’s MIRAS Demonstrator Pilot Project-2 (MDPP-2) under a subcontract for EADS-CASA. Other partners in the MDPP-2 NIR project are Toikka Engineering ...
متن کاملMicrowave Radiometer for Cloud Carthography: A 22channel groundbased microwave radiometer for atmospheric research
A 22-channel Microwave Radiometer for Cloud Carthography (MICCY) for the profiling of tropospheric temperature, humidity, and cloud liquid water has been developed. The radiometer has 10 channels along the high-frequency wing of the 22.235 GHz water vapor line, 10 channels along the low-frequency side of the 60 GHz oxygen complex, and 2 channels at 90 GHz. Two features make the radiometer a uni...
متن کامل