Macular Perfusion Parameters in Different Angiocube Sizes: Does The Size Matter in Quantitative Optical Coherence Tomography Angiography?

نویسندگان

  • Alessandro Rabiolo
  • Francesco Gelormini
  • Alessandro Marchese
  • Maria Vittoria Cicinelli
  • Giacinto Triolo
  • Riccardo Sacconi
  • Lea Querques
  • Francesco Bandello
  • Giuseppe Querques
چکیده

Purpose To investigate the macular quantitative parameters interchangeability of three different optical coherence tomography angiography (OCT-A) angiocubes (i.e., 3 × 3, 6 × 6, and 12 × 12 mm) on healthy subjects and patients affected by diabetic retinopathy (DR) and to assess the interrater reliability of such indices across the different scan protocols. Methods Retrospective study involving 20 eyes of healthy subjects and 20 eyes with DR. All eyes underwent swept-source OCT-A with 3 × 3-, 6 × 6-, and 12 × 12-mm angiocubes centered on the fovea. Foveal avascular zone (FAZ) area and vessel density on 3 × 3-, 6 × 6-, and 12 × 12-mm macular scans were calculated by three independent operators at all retina, superficial, deep, and choriocapillary vascular layers. Interchangeability and interrater reliabilities were estimated using intraclass correlation coefficient (ICC). Results Interscan reproducibility of FAZ area was very strong (ICC > 0.85) at every plexus. On the contrary, vessel density values significantly varied across different scan sizes (ICC < 0.51). Intrascan interrater reliability was high for all retina and superficial FAZ areas, while it was satisfactory at deep capillary plexus only for 3 × 3-mm scan. Conclusions FAZ area at all plexuses is a robust parameter even if calculated on angiocubes with different size. However, interrater reliability is higher when measured in smaller scans. Conversely, vessel density results depend on the size of angiocube, although their interrater reliability is extremely high. Studies involving OCT-A should take into consideration that scan size may influence macular perfusion parameters and interrater reliability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Evaluation of Optical Coherence Tomography Angiography Findings in Patients with Branch Retinal Vein Occlusion

Purpose: To analyze the correlation of optical coherence tomography angiography (OCTA) findings with visual acuity (VA) in patients with branch retinal vein occlusion (BRVO). Methods: This cross-sectional study was performed on 20 eyes of 20 patients with unilateral BRVO involving the macula referred to the ophthalmology clinic of Rassoul Akram Hospital. OCTA imaging was conducted for all patie...

متن کامل

Evaluation of the Vascular Density, the Area of Foveal Avascular Zone, and Corrected Vision in Patients with Diabetic Macular Edema after Anti-VEGF Therapy

Background and Objective: This study aimed to evaluate the changes in macular superficial and deep capillary plexus (SCP and DCP) density, Foveal Avascular Zone (FAZ) area, and visual acuity in patients with diabetic macular edema after anti-VEGF therapy. Materials and Methods: This descriptive-analytical study utilized before and after treatment design. In total, 30 eyes of 30 patients with d...

متن کامل

Optical Coherence Tomography Angiography to Better understand Glaucoma

The term optical coherence tomography angiography (OCTA) comprises different OCT-based technologies which all allow noninvasive assessment of retinal perfusion, based on moving red blood cells. The main areas where OCTA is currently used are investigation of perfusion and vascular structure of the macular retina (e.g., in macular degenerations and diabetic macular diseases) and the disk and per...

متن کامل

Reproducibility of Perfusion Parameters of Optic Disc and Macula in Rhesus Monkeys by Optical Coherence Tomography Angiography

BACKGROUND Optical coherence tomography (OCT) angiography is a novel technique by which we can detect the local perfusion of fundus directly. The aim of this study was to evaluate the reproducibility of optic disc and macular flow perfusion parameters in rhesus monkeys using OCT angiography. METHODS Eighteen healthy monkeys (18 eyes) were subjected to optic disc and macula flow index measurem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 2018