Effect of an interactive cardiopulmonary resuscitation assist device with an automated external defibrillator synchronised with a ventilator on the CPR performance of emergency medical service staff: a randomised simulation study

نویسندگان

  • Rainer Nitzschke
  • Christoph Doehn
  • Jan F. Kersten
  • Julian Blanz
  • Tobias J. Kalwa
  • Norman A. Scotti
  • Jens C. Kubitz
چکیده

BACKGROUND The present study evaluates whether the quality of advanced cardiac life support (ALS) is improved with an interactive prototype assist device. This device consists of an automated external defibrillator linked to a ventilator and provides synchronised visual and acoustic instructions for guidance through the ALS algorithm and assistance for face-mask ventilations. METHODS We compared the cardiopulmonary resuscitation (CPR) quality of emergency medical system (EMS) staff members using the study device or standard equipment in a mannequin simulation study with a prospective, controlled, randomised cross-over study design. Main outcome was the effect of the study device compared to the standard equipment and the effect of the number of prior ALS trainings of the EMS staff on the CPR quality. Data were analysed using analyses of covariance (ANCOVA) and binary logistic regression, accounting for the study design. RESULTS In 106 simulations of 56 two-person rescuer teams, the mean hands-off time was 24.5% with study equipment and 23.5% with standard equipment (Difference 1.0% (95% CI: -0.4 to 2.5%); p = 0.156). With both types of equipment, the hands-off time decreased with an increasing cumulative number of previous CPR trainings (p = 0.042). The study equipment reduced the mean time until administration of adrenaline (epinephrine) by 23 s (p = 0.003) and that of amiodarone by 17 s (p = 0.016). It also increased the mean number of changes in the person doing chest compressions (0.6 per simulation; p < 0.001) and decreased the mean number of chest compressions (2.8 per minute; p = 0.022) and the mean number of ventilations (1.8 per minute; p < 0.001). The chance of administering amiodarone at the appropriate time was higher, with an odds ratio of 4.15, with the use of the study equipment CPR.com compared to the standard equipment (p = 0.004). With an increasing number of prior CPR trainings, the time intervals in the ALS algorithm until the defibrillations decreased with standard equipment but increased with the study device. CONCLUSIONS EMS staff with limited training in CPR profit from guidance through the ALS algorithm by the study device. However, the study device somehow reduced the ALS quality of well-trained rescuers and thus can only be recommended for ALS provider with limited experience.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Survival and outcomes following cardiopulmonary resuscitation; a descriptive study in Iran

Objective: Cardiopulmonary resuscitation (CPR) has been known in its present form since 1960. Different studies have reported variable outcomes among different countries. Therefore, the purpose of this study was to assess the rate of CPR success and the survival rate in managing cardiac arrest among patients in an educational medical center. Methods: Th...

متن کامل

Effect of automatic external defibrillator audio prompts on cardiopulmonary resuscitation performance.

OBJECTIVES To determine the effectiveness of the cardiopulmonary resuscitation (CPR) audio prompts in an automatic external defibrillator in 24 lay subjects, before and after CPR training. METHODS Untrained subjects were asked to perform CPR on a manikin with and without the assistance of audio prompts. All subjects were then trained in CPR, and retested them eight weeks later. RESULTS Untr...

متن کامل

Hospital employees' theoretical knowledge on what to do in an in-hospital cardiac arrest

BACKGROUND Guidelines recommend that all health care professionals should be able to perform cardiopulmonary resuscitation (CPR), including the use of an automated external defibrillator. Theoretical knowledge of CPR is then necessary.The aim of this study was to investigate how much theoretical knowledge in CPR would increase among all categories of health care professionals lacking training i...

متن کامل

Outcomes of cardiopulmonary resuscitation in the emergency department

Objective: Cardiopulmonary resuscitation (CPR) is a lifesaving technique useful in the prevention of death or delaying it in a person with cardiac arrest. In this regard, demographic information about patients who need CPR is vital. Methods: In this cross-sectional study patients with cardiopulmonary arrest or arrhythmias admitted to Imam Reza and Sina ed...

متن کامل

Evaluation of a new semiautomated external defibrillator technology: a live cases video recording study.

AIM To determine the effect of a new automated external defibrillator (AED) system connected by General Packet Radio Service (GPRS) to an external call centre in assisting novices in a sudden cardiac arrest situation. METHOD Prospective, interventional study. Layperson volunteers were first asked to complete a survey about their knowledge and ability to give cardiopulmonary resuscitation (CPR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 25  شماره 

صفحات  -

تاریخ انتشار 2017