Acute non-hemolytic transfusion reactions and HLA class I antibody: advantages of solid phase assay compared with conventional complement-dependent assay

نویسندگان

  • S Imoto
  • K Kawamura
  • Y Tokumine
  • N Araki
  • S Akita
  • C Nishimura
  • H Inaba
  • K Saigo
  • O Mabuchi
  • H Okazaki
چکیده

To evaluate the specific reactivity of HLA Class I antibodies (HLA-I Abs) in acute non-hemolytic transfusion reactions (ANHTRs) using solid phase assays (SPAs) and conventional complement-dependent lymphocyte cytotoxicity test (LCT). ANHTRs are major issues in transfusion medicine. Anti-leukocyte antibodies have been implicated as one of the causative agents of transfusion-related acute lung injury (TRALI) and febrile reaction. Antibodies to HLA Class I and/or Class II (HLA Abs) have been intensively studied using SPAs for TRALI, but not for febrile reaction. About 107 patients and 186 donors associated with ANHTRs were screened for HLA Abs by SPAs such as enzyme-linked immunosorbent assay (ELISA) and the Luminex method. When HLA-I Ab was detected, its specific reactivity was evaluated by comparing its specificity identified by the Luminex method using recombinant HLA molecules and cognate HLA antigens (Ags), as well as LCT with or without anti-human globulin (AHG). The incidences of HLA Abs were as high as 32.7% of patients' serum samples and 16% of donors' serum samples. The incidence of HLA-I Abs did not differ significantly between cases of febrile and allergic reactions. However, HLA-I Abs associated with febrile reaction showed a significantly higher rate of possessing specific reactivity to cognate HLA Ags than those associated with allergic reactions. In addition, the Luminex method enabled the detection of HLA-I Abs much earlier than AHG-LCT in serum samples from a patient with febrile reaction and platelet transfusion refractoriness (PTR). SPAs seem more useful than AHG-LCT for evaluating reactivity of antibodies in ANHTR cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel solid phase-based ELISA assays contribute to an improved detection of anti-HLA antibodies and to an increased reliability of pre- and post-transplant crossmatching

Antibodies directed against HLA antigens of a given organ donor represent the dominating reason for hyper-acute or acute allograft rejections. In order to select recipients without donor-specific antibodies, a standard crossmatch (CM) procedure, the complement-dependent cytotoxicity assay (CDC), was developed. This functional assay strongly depends on the availability of isolated vital lymphocy...

متن کامل

Detection of HLA Antibodies in Organ Transplant Recipients – Triumphs and Challenges of the Solid Phase Bead Assay

This review outlines the development of human leukocyte antigen (HLA) antibody detection assays and their use in organ transplantation in both antibody screening and crossmatching. The development of sensitive solid phase assays such as the enzyme-linked immunosorbent assay technique, and in particular the bead-based technology has revolutionized this field over the last 10-15 years. This revol...

متن کامل

Donor-specific HLA class I and CREG antibodies in complement-dependent cytotoxicity-negative renal transplants.

Development of a solid-phase, single antigen panel reactive antibody test (SA-PRA) permits the analysis of antibody specificities. This study determined the impact of donor-specific antibodies (DSA) against class I HLA private antigens (DS-HLA) or HLA-A and -B cross-reactive group (DS-CREG) in kidney transplantation. Pre- and post-transplant sera of 133 renal allograft patients who had negative...

متن کامل

Methodologies for anti-HLA antibody screening in patients awaiting kidney transplant: a comparative study.

OBJECTIVES The relevance of anti-HLA antibodies in patients awaiting kidney transplants is well recognized. During the past 40 years, kidney transplant candidates have been tested for these antibodies, and the choice of the detection assay has become essential. Recently, the pioneer method, the complement-dependent cytotoxicity, has been integrated but has not been replaced by more-sensitive so...

متن کامل

Kinetics of HLA antibodies: A Titanic effort is required

Recently, Jackman et al., have published a very interesting paper entitled ‘Low-level HLA antibodies do not predict platelet transfusion failure in TRAP study participants.1 The authors have profoundly explained the possible mechanisms that might be responsible for the platelet refractoriness in the 19% of recipients who had no detectable human leukocyte antigens (HLA) antibodies using the lymp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2010