Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.
نویسندگان
چکیده
BACKGROUND The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements performed by LC-MS, a clinically available immunoturbidimetric assay, and size-exclusion HPLC. METHODS We obtained unused clinical urine samples from 150 patients who were stratified by degrees of albuminuria (<20 mg/L, 20-250 mg/L, >250 mg/L) as determined by the immunoturbidimetric assay used in our clinical laboratory (Roche Hitachi 912). Urine albumin was then remeasured via LC-MS and HPLC (Accumin) assays. RESULTS The immunoturbidimetric assay, calibrated using manufacturer-supplied serum-derived calibrators (Diasorin), underestimated albumin compared with LC-MS. After calibration with purified HSA, this immunoturbidimetric assay correlated well with LC-MS. HPLC overestimated albumin compared with both LC-MS and immunoturbidimetry. The current LC-MS and HPLC assays both performed poorly at concentrations <20 mg/L. CONCLUSIONS Efforts are needed to establish gold-standard traceable calibrators for clinical assays. LC-MS is a specific method to quantify albumin in native urine when concentrations exceed 20 mg/L, and therefore could be employed for standardization among assays.
منابع مشابه
Quantification of urinary albumin by using protein cleavage and LC-MS/MS.
BACKGROUND Urinary albumin excretion is a sensitive diagnostic and prognostic marker for renal disease. Therefore, measurement of urinary albumin must be accurate and precise. We have developed a method to quantify intact urinary albumin with a low limit of quantification (LOQ). METHODS We constructed an external calibration curve using purified human serum albumin (HSA) added to a charcoal-s...
متن کاملQuantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملQuantification of identical and unique segments in ethylene-propylene copolymers using two dimensional liquid chromatography with infra-red detection
Hyphenating High Temperature High Performance Liquid Chromatography (HT-HPLC) with High Temperature Size Exclusion Chromatography (HT-SEC) (High Temperature Two Dimensional Liquid Chromatography (HT-HPLC x HT-SEC or HT 2D-LC)) leads to an isocratic elution in the second dimension, which in turn enables to use IR detector (quantitative detection) for monitoring the eluting polymers. Experimental...
متن کاملPerformance characteristics of an HPLC assay for urinary albumin.
Microalbuminuria is a marker of diabetic nephropathy and cardiovascular risk. Immunoassays underestimate the amount of intact albumin present in urine. The purpose of this study was to evaluate a new urinary albumin assay that uses size exclusion high-performance liquid chromatography (HPLC). We determined the limit of detection, linearity, imprecision, a comparison with an immunoturbidimetric ...
متن کاملCoelution of other proteins with albumin during size-exclusion HPLC: Implications for analysis of urinary albumin.
BACKGROUND Size-exclusion HPLC has been used as an alternative to immunoassays for quantifying urinary albumin (microalbumin). Systematically higher values for the HPLC method have been proposed to result from nonimmunoreactive albumin. METHODS We evaluated separation of purified proteins and urinary components by size-exclusion HPLC using a Zorbax Bio Series GF-250 column eluted with phospha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 54 9 شماره
صفحات -
تاریخ انتشار 2008