Forced oscillation technique and spirometry in cold air provocation tests.

نویسندگان

  • G J Wesseling
  • I M Vanderhoven-Augustin
  • E F Wouters
چکیده

BACKGROUND Impedance measurements by the forced pseudo random noise oscillation technique can be used to study the mechanical characteristics of the respiratory system. The objective of this study was to analyse the changes in impedance to a cold air provocation test in patients with asthma, and to correlate these changes with those in the forced expiratory volume in one second (FEV1). METHODS The response to isocapnic hyperventilation with cold air was assessed by respiratory impedance measurements and spirometry in 60 patients with bronchial asthma in whom the provocative dose of histamine resulting in a 20% fall in FEV1 (PD20) was < or = 8 mumol. RESULTS Cold air provocation resulted in a mean(SD) fall in FEV1 from 3.75(0.85) litres to 3.10(0.90) litres. The mean(SD) decrease in FEV1 as a percentage of predicted was 15.4(3.8)%. The oscillatory resistance at 8 Hz increased from a mean(SD) of 0.367(0.108) kPa/l/s to 0.613(0.213) kPa/l/s and at 28 Hz the resistance increased from 0.348(0.089) to 0.403(0.099) kPa/l/s. Frequency dependence of resistance became significantly more negative. The reactance at 8 Hz decreased from a mean(SD) of -0.035 (0.041) kPa/l/s to -0.234(0.199) kPa/l/s, and the resonant frequency increased from 12.5(4.9) Hz to 25.7(9.1) Hz. Significant correlations were calculated between the decrease in FEV1 and changes in the various impedance parameters, especially between the decrease in FEV1 and the increase in resistance at 8 Hz (r = -0.66), and the decrease in FEV1 and the increase in the resonant frequency (r = -0.63). CONCLUSION Cold air provocation in asthmatic subjects results in changes in the impedance of the respiratory system that correlate well with the changes in FEV1. These changes in impedance reflect ventilatory inhomogeneities in the peripheral compartment of the bronchial tree. These observations show the value of this technique in the evaluation of induced bronchoconstriction, as both a quantitative and a qualitative analysis of the response is possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The diagnostic capacity of forced oscillation and forced expiration techniques in identifying asthma by isocapnic hyperpnoea of cold air.

The measurement of forced expiratory volume in one second (FEV1) is often used to assess the effect of bronchial provocations, and deep inspiration is required beforehand. This may briefly alter the bronchial tone in a variable way in some subjects. The forced oscillation technique (FOT) is a test used to characterize the mechanical impedance of the respiratory system, and prior deep inspiratio...

متن کامل

Using the forced oscillation technique to evaluate bronchodilator response in healthy volunteers and in asthma patients presenting a verified positive response.

OBJECTIVE To use the forced oscillation technique to evaluate asthma patients presenting positive bronchodilator responses (confirmed through spirometry) and compare the results with those obtained in healthy individuals. METHODS The study sample consisted of 53 non-smoking volunteers: 24 healthy subjects with no history of pulmonary disease and 29 asthmatics presenting positive bronchodilato...

متن کامل

Responsiveness to three bronchial provocation tests in patients with asthma.

STUDY OBJECTIVES To compare a new bronchial provocation test, the mannitol challenge, with cold air and histamine challenges to demonstrate airway hyperresponsiveness (AHR) in patients with difficult-to-diagnose asthma. DESIGN A prospective study. PARTICIPANTS Thirty-seven consecutive patients with recently diagnosed, steroid-naive, mild, or atypical asthma fulfilling the diagnostic criteri...

متن کامل

Measurement of bronchial responsiveness by forced oscillation technique in occupational epidemiology.

The performance of the forced oscillation technique (FOT) in the assessment of bronchial responsiveness on the methacholine challenge test was compared with that of forced expiratory volume in one second (FEV1) in 119 active workers with normal baseline pulmonary function. Changes in resistance (delta R0%), frequency dependence of resistance (delta P) and resonant frequency (delta F%) determine...

متن کامل

The forced oscillation technique in clinical practice: methodology, recommendations and future developments.

The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mechanics. FOT employs small-amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory manoeuvres. The present European Respiratory Society Task Force Report ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 1993