Skinfold Thickness Measurement in Term Nigerian Neonates: Establishing Reference Values
نویسندگان
چکیده
Skin fold thickness (SFT) measurement is a reliable, cheap, simple, noninvasive method of body fat estimation at all ages including the neonatal period. Objective. To determine reference values of biceps, triceps, subscapular, and suprailiac skinfold thickness measurements in term Nigerian newborns. Method. A prospective cross-sectional study over a six-month period (Dec 2010-May 2011) was carried out on term and healthy neonates delivered between 37 and 41 weeks. The anthropometric measurements were taken within the first 48 hours of life including the skinfold thickness. The skinfold thickness measurements were taken at four sites, namely, triceps, biceps, subscapular, and suprailiac, using Harpenden skinfold calipers. The mean of two readings was recorded. Result. A total of one thousand one hundred and sixty-eight neonates were studied. The birth weight ranged between 2000 g and 5000 g with a mean birth weight of the neonates at 3259 ± 470 g. The mean birth weight of the males (3339 ± 0.45) was significantly higher than that of females (3200 ± 0.44) (p < 0.0001). Female neonates had higher mean values of triceps, subscapular, and suprailiac skinfold thickness (p < 0.001, resp.) while male neonates had higher mean value of biceps skinfold thickness (p = 0.008). Females also had higher mean values of the sum of skinfold thicknesses at all four sites and the sum at the two truncal sites at every stratified gestational age. Conclusions. The sex specific percentile chart developed for skinfold thickness measurements can be used to detect deviation from the reference population such that infants who are at risk of nutritional or health problems are identified early, and intervention is instituted promptly.
منابع مشابه
Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study
Assessing neonatal size reliably is important for research and clinical practice. The aim of this study was to examine the reliability of routine clinical measurements of neonatal circumferences and of skinfold thicknesses assessed for research purposes. All measurements were undertaken on the same population of neonates born in a large maternity unit in Bradford, UK. Technical error of measure...
متن کاملThe Relationship between Skinfold Thickness and Body Mass Index in Estimating Body Fat Percentage on Bowen University Students
Body Mass Index (BMI) is a weight-to-height ratio used as a quick and easy guide to obesity classification. BMI of 30 or greater is indicative of excess body fat and has been labelled as increasing the risk of degenerative diseases such as cardiovascular disease and diabetes. Body fat percentage is also assessed through skinfold thickness measurement.. The aim of this study was to estimate the ...
متن کاملBody fat in neonates and young infants: validation of skinfold thickness versus dual-energy X-ray absorptiometry1–3
Background: There is an interest in noninvasive measurement of body fat in newborns and infants. Measurement of skinfold thickness (SFT) is a simple clinical method. Objective: We correlated fat mass (FM) values of neonates and infants predicted from SFT measurements and compared them with FM values measured by dual-energy X-ray absorptiometry (DXA), a validated in vivo method for determining b...
متن کاملBody fat in neonates and young infants: validation of skinfold thickness versus dual-energy X-ray absorptiometry.
BACKGROUND There is an interest in noninvasive measurement of body fat in newborns and infants. Measurement of skinfold thickness (SFT) is a simple clinical method. OBJECTIVE We correlated fat mass (FM) values of neonates and infants predicted from SFT measurements and compared them with FM values measured by dual-energy X-ray absorptiometry (DXA), a validated in vivo method for determining b...
متن کاملNeonatal skinfold thickness. Measurement and interpretation at or near term.
Skinfold thickness was measured at five sites in 750 infants. The study population was unselected except that twin pregnancies and the infants of diabetic mothers were excluded, and very preterm infants were under represented. A pilot study had indicated that skinfold measurement was most reproducible at the thigh site. Thigh skinfold correlated better with the sum of other skinfolds than did s...