Relative value of commercial kits for ANA testing.
نویسندگان
چکیده
AIMS We have tested the relative performance of 20 commercial ANA test kits along with that of our own laboratory to assess whether one was clearly superior. METHODS The sera were drawn from 3 pools that had all been pre-tested in our laboratory: patients with definite SLE; patients with non-connective tissue diseases (CTD), but where a positive FANA had been found; and normal blood donors. The tests were used in accordance with the recommendations of the specific supplier but in a routine serology laboratory. RESULTS Sensitivity and specificity ranged between 38 and 100%. While the negative predictive value of 4 ELISA kits was 100%, and most others were close, the HEp-2 kits were 100% in only 1 case. A positive predictive value of 100% was also seen with 1 kit. CONCLUSION Some of the tests are clearly better than others, but the choice may differ depending on the clinical needs, e.g. preference for a good positive or negative predictive value. However, the ELISA kits offered better results than the immunofluorescent technique. Two of them had sensitivity/specificity of > 90%.
منابع مشابه
Evaluation of commercial ELISA kits for the detection of antibodies against bluetongue virus.
The aim of this study was to estimate the diagnostic value of different commercially available ELISA kits for the detection of bluetongue virus (BTV) antibodies in infected and vaccinated animals. The relative specificity of ELISA kits was evaluated using a panel of sera originating from healthy cattle, never vaccinated nor exposed to BTV. All ELISA kits applied had a high relative specificity ...
متن کاملInappropriate use of commercial Antinuclear Antibody Testing in a community-based US hospital: a retrospective study
Healthcare providers use antinuclear antibodies (ANAs) to screen and diagnose patients with autoimmune diseases. In the recent years, commercial multiplex ANA kits have emerged as a convenient and fast diagnostic method. Diagnostic testing should follow sequenced algorithms: initial screen followed by specific antibody analysis. Second-level testing as an initial screen for autoimmune disease i...
متن کاملSuitability of various control sera for use in testing the accuracy of cholesterol determination with enzymic kits.
We used 20 different commercial enzymic kits to measure cholesterol in 19 commercial control sera and in a pooled specimen of human serum and compared the relative biases, with the Abell -Kendall procedure as reference. Our purpose was to select those sera in various enzymic kits showing behavior similar to that of human serum and which thus can be used to measure the accuracy of these kits. Th...
متن کاملCoagulase testing compared with commercial kits for routinely identifying Staphylococcus aureus.
Five commercial Staphylococcus aureus identification kits--Staphaurex (Wellcome), Staphylase (Oxoid), Staphyslide (bioMèrieux), Biostaph (Medlabs) and Bacto Latex (Difco)--were evaluated for the routine identification of S aureus from primary plates in the routine microbiology laboratory. Comparison was made with two methods of tube coagulase testing and five slide methods for detecting clumpin...
متن کاملComparative analysis of different commercial ELISA systems for the detection of anti-neutrophil cytoplasm antibodies in ANCA-associated vasculitides.
OBJECTIVES To assess the diagnostic performance of 11 commercial PR3- and MPO-ANCA ELISA systems (direct, capture and high sensitive [hs] ELISA). METHODS Sera from 90 patients with AAV (GPA, MPA and CSS) and 20 disease controls (SLE; RA) and healthy individuals were tested for the presence of ANCA by IFT and by different ELISAs for the presence of PR3-and MPO-ANCA, respectively. Furthermore, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical and experimental rheumatology
دوره 21 4 شماره
صفحات -
تاریخ انتشار 2003